Id | Code | Select the type of water source being inspected | Select the agency inspecting this water source | Enter the date of source inspection | Region | District | Enter the name of settlement / village where the source is located | Distance to nearest settlement (KM) | Select the agency that established this water source | Enter the date when the source was established | Enter the water source name | Source gpspoint | Enter water source Latitude in decimal degrees | Enter water source Longitude in decimal degrees | Enter Elevation (m.a.s.l) | Enter GPS Precision (m) | Enter number of water sources in a cluster | Water Source Photographs | Select the category of users for this water source | Is this a permanent status water source? | For how many months in a year is this water source in use (#)? | Is this water source currently functioning? | Non functioning reason | No. of persons using | No. of Camels using the source | No. of Cattle using the source | No. of Sheep/Goats using the source | Area irrigated using the source (ha) | Is the source protected? | What is the depth of this borehole (m)? | Type of Casing | Casing size (inches) | What is the current static water level of this borehole (m)? | What is the yield of this borehole (m3/hr)? | How long is this borehole operated in a day (hr)? | What is the borehole draw down (m)? | After pumping, how long does this borehole take to recover (hr)? | What is the depth of this dug well (m)? | What is the current static water level of this dug well (m)? | What is the yield of this dug well (m3/hr)? | How long is this dug well operated in a day (hr)? | What is the dug well draw down (m)? | After pumping, how long does this dug well take to recover (hr)? | What is the depth of this dam (m)? | What is the length of this dam (m)? | What is the width of this dam (m)? | What is the depth of this berkad (m)? | What is the length of this berkad (m)? | What is the width of this berkad (m)? | What is the cumulative discharge rate of this spring (m3/hr)? | What is the depth of this source (m)? | What is the length of this source (m)? | What is the width of this source (m)? | What is the yield of the source (m3/hr)? | What type of reservoir is used for this source? | Reservoir capacity (m3) | Pipeline type | Pipeline length (m) | How many House Holds (HH) are connected to this water source? | How many kiosks/water points are connected to this source? | How many animal troughs are connected to this source? | Source used for water trucking during emergency? | No. of trucks / day | Average truck capacity (m3) | Pump type | Pump model | Pump capacity (m3/hr) | Pump level (m) | Power source | Generator/Solar type | Generator capacity (kVA/kWh) | What type/model is the solar used? | What capacity is the solar (kWh)? | Condition of supply system | Additional notes on supply & distribution system condition | Any visible physical problem (color, odor)? | Please describe the color, odor and smell of water | Temperature | PH | Electrical Conductivity (µs/cm) | Total Dissolved Solids (mg/l) | Water sample code. (if taken) | Management type | Water & Sanitation Committee (WSC)? | Year established | WSC members male | WSC members female | DIs water for human use charged? | Current cost of 20 ltr jerrican (USD/20ltr) | Is water for animal use charged? | Current cost for Livestock (USD/100ltr) | What is the name of the operator/caretaker for this water source? | What is the phone number of the operator/caretaker? | Which agency carried out last intervention on this water source? | Recent interventions | Last intervention date | Proposed intervention description | Additional Notes | Metadata Tag |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
7154 | — | Dug Well | FGS Ministry of Energy and Water Resources | March 26, 2022 | Lower Shabelle | afgooye | — | 2.0 | Private | 01/01/2007 | Ceelka Cabdikariim | — | 2.1501408 | 45.1164217 | 62.0 | — | 5 | — | rural | yes | — | Yes | — | 1400 | 0 | 300 | 200 | 3.0 | — | — | — | — | — | — | — | — | — | 27.0 | 7.0 | 1.0 | 24.0 | 2.0 | 1.0 | — | — | — | — | — | — | — | — | — | — | — | Plastic tank | 2.0 | PVC | 2000.0 | 200 | 0 | 0 | yes | 0 | 0.0 | Submersible Pump | Japan | 1.0 | 2.0 | Generator | 115 | 3.0 | — | — | good | I am using 3 pumps | yes | No | 0.0 | — | — | — | — | Communal | no | — | — | — | yes | 0.1 | yes | — | — | — | Private | 21-Mar-21 | 5 | Diging well, maintaining water tank | — | — |
7585 | — | Dug Well | Puntland Ministry of Energy Minerals and Water | March 17, 2022 | Bari | iskushuban | Dardaare village | 1.0 | Puntland MoEMW | 18/12/2010 | Dardaare dug well | — | 10.4237422 | 50.9179111 | -8.0 | — | 2 | — | urban rural | yes | — | Yes | — | 900 | 150 | — | 900 | — | — | — | — | — | — | — | — | — | — | 10.0 | 8.0 | 4.0 | 10.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 24.0 | PVC | 1000.0 | — | 9 | 1 | no | — | — | Submersible Pump | Grundforse | — | 9.0 | Hybrid - Solar/Generator | KAMA | 4.0 | — | — | fair | The yield of dug well is very low. The solar power system has no more KVA. | no | — | 27.9 | 7.3 | 3530.0 | 1776.0 | — | Communal | yes | 21/07/2012 | 4 | 3 | yes | 0.04 | no | — | — | — | CARE Somalia | 16/02/2022 | Construction of elevated water tank. Construction of 2 kiosks. | 1: The dug well is located near to the river, thus construction of retaining wall which protect the dug well is necessary. 2: Construction of kiosks. 3: extension of pipe lines to the village. 4: submersible pump. 5: Construction of animal troughs. | — | — |
7772 | — | Dug Well | Puntland Ministry of Energy Minerals and Water | April 3, 2022 | Sool | las_caanood | Xudun | 0.0 | Community | 03/04/2007 | Xudun dug well | — | 9.1538636 | 47.4780043 | 599.0 | — | 2 | — | urban | yes | — | Yes | — | 4500 | — | — | — | — | — | — | — | — | — | — | — | — | — | 10.0 | — | 5.0 | 12.0 | — | 3.0 | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 86.0 | PVC | 1500.0 | 50 | 10 | 0 | yes | 20 | 6.0 | Submersible Pump | Grandfoss | 1.2 | 3.0 | Hybrid - Solar/Generator | — | 5.0 | — | 8.0 | fair | — | yes | Colorless and odorless | 29.5 | 7.5 | 4500.0 | 3015.0 | — | Communal | yes | 03/04/1989 | 4 | 3 | yes | 0 | no | — | — | — | DRC | 03/04/2022 | 1. Construction of elevated water tank | 1. Rehabilitation of generator 2. Extension pipelines 3. Rehabilitation of dug well. | — | — |
7447 | — | Dug Well | FGS Ministry of Energy and Water Resources | March 29, 2022 | Lower Shabelle | afgooye | Aaytiro | 2.0 | Community | 29/03/2020 | Ibnu Maxamed water supply | — | 2.1470624 | 45.1183974 | 53.0 | — | 1 | — | rural | yes | — | Yes | — | 1260 | 0 | 0 | 0 | 0.0 | — | — | — | — | — | — | — | — | — | 14.0 | 5.0 | 21.0 | 24.0 | 3.0 | 1.0 | — | — | — | — | — | — | — | — | — | — | — | Plastic tank | 3.0 | PVC | 1.0 | 180 | 1 | 0 | yes | 2 | 6.0 | Submersible Pump | 3.5 - 4 Italian | 4.0 | 2.0 | Generator | Gencava 150 | 5.0 | — | — | good | Distribution of families who live in the area | no | — | 0.0 | — | — | — | — | Communal | yes | 29-Jun-21 | 3 | 2 | yes | 0.1 | no | — | — | — | Community | 1-Jan-22 | Pipeline and pump repair | Excavation of the depth, construction of new water tank, New generator and pump. Design for solar system for future | — | — |
7392 | — | Dug Well | FGS Ministry of Energy and Water Resources | March 24, 2022 | Bakool | xudur | Saweeda shallow well | 1.0 | GRRN | 24/03/2022 | Saweeda shallow well | — | 4.1268699 | 43.8912627 | 474.0 | — | 15 | — | rural urban | yes | — | Yes | — | 1900 | 0 | 0 | 0 | 0.0 | — | — | — | — | — | — | — | — | — | 10.0 | 6.0 | 15.0 | 12.0 | 9.0 | 1.0 | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 25.0 | PVC | 6.0 | 0 | 0 | 0 | no | — | — | Submersible Pump | Hanti | 1.5 | 9.0 | Generator | Gengfa | 5.0 | — | — | fair | Less of capacity of water pumping systems | no | — | 17.0 | 6.0 | 5000.0 | 600.0 | — | Private/Individual | — | — | — | — | yes | 0.3 | no | — | — | — | GRRN | 24-Mar-22 | Elevated water tank and submersible pupm caretaker room | Rehabilatation of water tank digging the well in depth of 2 miter installation of solar system | — | — |
7801 | — | Dug Well | FGS Ministry of Energy and Water Resources | March 25, 2022 | Bakool | xudur | Madawarabe | 7.0 | Community_ | 16/10/2007 | Godow shallow well2 | — | 4.1408792 | 43.9305709 | 444.0 | — | 4 | — | rural | yes | — | Yes | — | 800 | 0 | 0 | 0 | 2.0 | — | — | — | — | — | — | — | — | — | 11.0 | 7.0 | 10.0 | 2.0 | 1.0 | 1.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 0 | 0 | 0 | no | — | — | Submersible Pump | Florence | 1.2 | 10.0 | Generator | Gengfa | 5.6 | — | — | good | The supply system is not fully completed required to install solar system care taker room construction of water tank and water points with pipeline extention | no | — | 15.0 | 7.0 | 5000.0 | 500.0 | — | Other | — | — | — | — | no | — | no | — | — | — | — | — | — | Construction of water tank installaion of solar system and submersible pupm fiencing for protection | — | — |
7391 | — | Dug Well | FGS Ministry of Energy and Water Resources | March 24, 2022 | Bakool | xudur | Bullow | 0.5 | GRRN | 25/03/2022 | Jiroomow shallow well | — | 4.1249479 | 43.8913415 | 471.0 | — | 10 | — | rural urban | no | 9 | Yes | — | 3000 | 0 | 0 | 0 | 0.0 | — | — | — | — | — | — | — | — | — | 11.0 | 7.0 | 2.0 | 1.0 | 7.0 | 2.0 | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 25.0 | PVC | 8.0 | 0 | 0 | 0 | no | — | — | Submersible Pump | Florence | 1.5 | 10.0 | Generator | Gengfa | 5.6 | — | — | fair | The water well is almost limited due to seaonal time in recommendations rehabilataion of water tank digging more miters in the depth and installation solar system with quality pupm | no | — | 16.0 | 7.0 | 5500.0 | 500.0 | — | Private/Individual | — | — | — | — | yes | 0.4 | no | — | — | — | GRRN | 25-Mar-22 | Construction of water tank caretaker room istallaion of 1.5 submersible pupm | Rehabilatation of water tank installation of new solar system and quality pupm | — | — |
3292 | DWGDDO005 | Dug Well | FGS_MoEWR | Oct. 4, 2019 | Gedo | Doolow | Gaawiido | — | Cadow Cabdi | 1/28/2018 | Dhuun2 | — | 3.9894 | 41.9189 | 200.0 | 4.9 | 1 | 1570179951920.jpg | — | yes | — | Yes | — | 3500 | — | — | — | — | No | — | — | — | — | — | — | — | — | 7.0 | 4.0 | 10.0 | 12.0 | 1.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | — | — | yes | 5 | 10.0 | — | Grundfos | 10.0 | 6.0 | Submersible Pump | Anil | 5.9 | — | — | — | This water source has no supply but trukcs fetch water from the well directly upon arrival then they provide wayer to the H h through tracking. | No | — | 32.2 | 7.8 | 1390.0 | 690.0 | — | — | — | — | — | — | Yes | 0.05 | No | — | — | — | — | — | — | Well head construction 1m above the ground, cover slab, Solar system 40 pannels 250w, elevated concrete tank 50M3, 15000 upvc supply and distribution pipeline, submersible pumb 7.5 and fence 8m2. | — | Strategic Water Sources Survey – WSS_NATl |
7960 | — | Dug Well | Galmudug Ministry of Energy and Water Resources | March 19, 2022 | Galgaduud | dhusa_marreb | Wadajir | 0.5 | Community | 23/06/2020 | Wadajir | — | 5.4949898 | 46.3484967 | 225.0 | — | 0 | — | rural | yes | — | Yes | — | 1500 | 100 | 0 | 450 | 64.0 | — | — | — | — | — | — | — | — | — | 18.0 | 13.0 | 6.0 | 12.0 | 5.0 | 0.2 | — | — | — | — | — | — | — | — | — | — | — | Steel tank | 10.0 | — | — | 0 | 0 | 0 | no | — | — | Submersible Pump | Not notified | 6.0 | 17.0 | Generator | King max | 6.5 | — | — | poor | 1. Not protect wall 2. Not have supply system | no | — | 33.5 | 6.73 | 2085.0 | 1042.0 | — | Communal | no | — | — | — | — | — | — | — | — | — | — | No | — | — | — | — |
7424 | — | Dug Well | Somaliland MoWRD | April 16, 2022 | Woqooyi Galbeed | hargeisa | Cadaadley district | 0.1 | UNICEF | 15/05/1991 | Cadaadley Dug well | — | 9.7682462 | 44.6896322 | 1245.0 | — | 20 | — | rural urban | yes | — | Yes | — | 2000 | 100 | 0 | 1500 | 0.0 | — | — | — | — | — | — | — | — | — | 4.0 | 3.0 | 3.0 | 6.6 | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 25.0 | Galvanised Steel | 500.0 | 300 | 3 | 0 | no | — | — | Submersible Pump | Capriri | 6.0 | 3.0 | Hybrid - Solar/Generator | Yanmer | 7.0 | — | 1.3 | poor | Very poor becouse of the pump and pipe and also droughts. | no | — | 29.0 | 7.6 | 1322.0 | 927.0 | — | Communal | no | — | — | — | yes | 0.12 | no | — | — | — | — | 11/07/2008 | Engine rehapilitation, solar instalation. | New dug well | — | — |