Id | Code | Select the type of water source being inspected | Select the agency inspecting this water source | Enter the date of source inspection | Region | District | Enter the name of settlement / village where the source is located | Distance to nearest settlement (KM) | Select the agency that established this water source | Enter the date when the source was established | Enter the water source name | Source gpspoint | Enter water source Latitude in decimal degrees | Enter water source Longitude in decimal degrees | Enter Elevation (m.a.s.l) | Enter GPS Precision (m) | Enter number of water sources in a cluster | Water Source Photographs | Select the category of users for this water source | Is this a permanent status water source? | For how many months in a year is this water source in use (#)? | Is this water source currently functioning? | Non functioning reason | No. of persons using | No. of Camels using the source | No. of Cattle using the source | No. of Sheep/Goats using the source | Area irrigated using the source (ha) | Is the source protected? | What is the depth of this borehole (m)? | Type of Casing | Casing size (inches) | What is the current static water level of this borehole (m)? | What is the yield of this borehole (m3/hr)? | How long is this borehole operated in a day (hr)? | What is the borehole draw down (m)? | After pumping, how long does this borehole take to recover (hr)? | What is the depth of this dug well (m)? | What is the current static water level of this dug well (m)? | What is the yield of this dug well (m3/hr)? | How long is this dug well operated in a day (hr)? | What is the dug well draw down (m)? | After pumping, how long does this dug well take to recover (hr)? | What is the depth of this dam (m)? | What is the length of this dam (m)? | What is the width of this dam (m)? | What is the depth of this berkad (m)? | What is the length of this berkad (m)? | What is the width of this berkad (m)? | What is the cumulative discharge rate of this spring (m3/hr)? | What is the depth of this source (m)? | What is the length of this source (m)? | What is the width of this source (m)? | What is the yield of the source (m3/hr)? | What type of reservoir is used for this source? | Reservoir capacity (m3) | Pipeline type | Pipeline length (m) | How many House Holds (HH) are connected to this water source? | How many kiosks/water points are connected to this source? | How many animal troughs are connected to this source? | Source used for water trucking during emergency? | No. of trucks / day | Average truck capacity (m3) | Pump type | Pump model | Pump capacity (m3/hr) | Pump level (m) | Power source | Generator/Solar type | Generator capacity (kVA/kWh) | What type/model is the solar used? | What capacity is the solar (kWh)? | Condition of supply system | Additional notes on supply & distribution system condition | Any visible physical problem (color, odor)? | Please describe the color, odor and smell of water | Temperature | PH | Electrical Conductivity (µs/cm) | Total Dissolved Solids (mg/l) | Water sample code. (if taken) | Management type | Water & Sanitation Committee (WSC)? | Year established | WSC members male | WSC members female | DIs water for human use charged? | Current cost of 20 ltr jerrican (USD/20ltr) | Is water for animal use charged? | Current cost for Livestock (USD/100ltr) | What is the name of the operator/caretaker for this water source? | What is the phone number of the operator/caretaker? | Which agency carried out last intervention on this water source? | Recent interventions | Last intervention date | Proposed intervention description | Additional Notes | Metadata Tag |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
7575 | — | Borehole | FGS Ministry of Energy and Water Resources | March 12, 2022 | Middle Shabelle | jowhar | Hanti Wadaag | 2.0 | Farjano | 10/02/2000 | Farjano | — | 2.7762449 | 45.4995161 | 106.0 | — | — | — | urban | yes | — | Yes | — | 7855 | — | — | — | — | — | 100.0 | gi | 8.0 | — | — | 10.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 100.0 | Galvanised Steel | 50.0 | 1850 | 8 | 0 | yes | 10 | 15.0 | Submersible Pump | Grandfos 18.5 KW | 60.0 | 60.0 | Generator | ALTERNATUER, LEROY - SOMER | 180.0 | — | — | poor | The generator is old the Solar panels are not enough and the submersible pump is poor | no | — | — | — | — | — | — | Private-Public-Partnership | — | — | — | — | yes | 0.05 | no | — | — | — | GSA | 12-Mar-22 | Supply of Generator, Installation of submersible pump, Rehabilitation of Generator room and Rehabilitation of Elevated water tank | Pipeline Extension | — | — |
7759 | — | Borehole | Galmudug Ministry of Energy and Water Resources | March 28, 2022 | Galgaduud | cabudwaaq | ubax | 5.0 | Community | 25/03/2013 | dur dur | — | 6.2506067 | 46.2367021 | 368.0 | — | 1 | — | urban rural | yes | — | Yes | — | 15000 | 1000 | — | 25000 | — | — | 120.0 | pvc | 8.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 80.0 | Galvanised Steel | 65.0 | 700 | 1 | 2 | yes | 5 | 9.0 | Submersible Pump | franglin | — | 102.0 | Generator | ATX | 32.0 | — | — | poor | — | no | — | 32.3 | 7.06 | 2310.0 | 1150.0 | — | Communal | yes | — | 3 | 2 | yes | 0.0015 | — | — | — | — | — | — | — | — | — | — |
7864 | — | Borehole | Somaliland MoWRD | April 23, 2022 | Sanaag | laasqoray | Balibusleh | 2.0 | Kuwait fund | 23/04/2014 | Balibusleh | — | 10.0501079 | 48.5866082 | 1009.0 | — | 0 | — | rural urban | yes | — | Yes | — | 1350 | 13000 | 1000 | 17000 | 0.0 | — | 144.0 | gi | 8.0 | 100.0 | 18.0 | 12.0 | 44.0 | 1.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 12.0 | Stainless Steel | 250.0 | 0 | 0 | 3 | yes | 2 | 10.0 | Submersible Pump | Groundfos | 18.0 | 75.0 | Generator | Adeulutz | 30.0 | — | — | fair | Insufficient water supply system | no | — | 29.0 | 7.5 | 3000.0 | 636.0 | — | Communal | no | — | — | — | no | — | no | — | — | — | — | — | 0 | 1.Solar pannel installation 2. Water tank 3. Animal trough 4. Watchman room | — | — |
7981 | — | Borehole | Somaliland MoWRD | April 7, 2022 | Sool | las_caanood | Higlo | 3.0 | Somaliland MoWRD | 07/04/2017 | Higlo borehole | — | 8.5553756 | 47.7281462 | 544.0 | — | 1 | — | rural urban | yes | — | Yes | — | 4500 | 17000 | 200 | 40000 | 12.0 | — | 65.0 | pvc | 8.0 | 45.0 | 16.0 | 12.0 | 0.0 | 0.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 16.0 | Galvanised Steel | 420.0 | 800 | 6 | 2 | yes | 5 | 8.0 | Submersible Pump | Laura | 15.0 | 45.0 | Hybrid - Solar/Generator | Adpower | 30.0 | M2 | 300.0 | good | All the system are working | no | — | 30.0 | 7.4 | 1900.0 | 1200.0 | — | Communal | no | — | — | — | no | — | no | — | — | — | Oxfam Novib | 07/04/2020 | Provision of generator construction water tank and extension pf pipelines | The system is working well and no considerable isssu reported | — | — |
3292 | DWGDDO005 | Dug Well | FGS_MoEWR | Oct. 4, 2019 | Gedo | Doolow | Gaawiido | — | Cadow Cabdi | 1/28/2018 | Dhuun2 | — | 3.9894 | 41.9189 | 200.0 | 4.9 | 1 | 1570179951920.jpg | — | yes | — | Yes | — | 3500 | — | — | — | — | No | — | — | — | — | — | — | — | — | 7.0 | 4.0 | 10.0 | 12.0 | 1.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | — | — | yes | 5 | 10.0 | — | Grundfos | 10.0 | 6.0 | Submersible Pump | Anil | 5.9 | — | — | — | This water source has no supply but trukcs fetch water from the well directly upon arrival then they provide wayer to the H h through tracking. | No | — | 32.2 | 7.8 | 1390.0 | 690.0 | — | — | — | — | — | — | Yes | 0.05 | No | — | — | — | — | — | — | Well head construction 1m above the ground, cover slab, Solar system 40 pannels 250w, elevated concrete tank 50M3, 15000 upvc supply and distribution pipeline, submersible pumb 7.5 and fence 8m2. | — | Strategic Water Sources Survey – WSS_NATl |
3290 | DWGDDO003 | Dug Well | FGS_MoEWR | Oct. 4, 2019 | Gedo | Doolow | Malkariyey | — | Ibrahim Shikh Muhumud( individual) | 11/29/2007 | Ibrahim sheikh | — | 3.9888 | 41.9164 | 198.0 | 4.5 | 2 | 1570175787243.jpg | — | yes | — | Yes | — | 3500 | 100 | 150 | 500 | 5.0 | No | — | — | — | — | — | — | — | — | 9.0 | 6.0 | 12.0 | 12.0 | 1.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | — | 1 | yes | 10 | 10.0 | — | Grundfos | 12.0 | 8.0 | Submersible Pump | Anil | 45.0 | — | — | — | — | No | — | 32.5 | 7.4 | 650.0 | 330.0 | — | — | — | — | — | — | Yes | 0.05 | No | — | — | — | — | — | — | Proposed intervention. Well head cover, elevated concrete water tank 50m3, solar system 48 pannel 250w. PIPELINE 10000M. NEW DUG WELL. Solar system 84 pannel/ generator changfa 115, elavated concrete tank 50m3. Supply pipeline 15000M. Well head cons | — | Strategic Water Sources Survey – WSS_NATl |
7635 | — | Borehole | Somaliland MoWRD | April 7, 2022 | Togdheer | burco | Burco | 0.1 | Action Afrika Hilfe e.V | 05/06/2014 | Timawaynta borehole | — | 9.5040633 | 45.5763478 | 1013.0 | — | 0 | — | urban | yes | — | Yes | — | 21000 | — | — | — | — | — | 154.0 | pvc | 8.0 | 108.0 | 32.0 | 18.0 | 0.0 | 0.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Other | 0.0 | PVC | 500.0 | 3000 | 0 | 0 | no | — | — | Submersible Pump | Grundfoz | 30.0 | 0.0 | Generator | Aska | 100.0 | — | — | good | Each and every household has connection and access botable water for their water demand. | no | — | 26.9 | 7.12 | 2462.0 | 906.0 | — | Communal | no | — | — | — | yes | 0.025 | no | — | — | — | — | 07/04/2022 | No intervention carried out | No intervention is required | — | — |
7875 | — | Borehole | Somaliland MoWRD | April 24, 2022 | Woqooyi Galbeed | gebiley | Arabsiyo | 1.0 | Mohamed Ali Barkhad | 20/04/2018 | Mukhtar Mohamed sh.Ahmed | — | 9.6473638 | 43.7621416 | 1386.0 | — | 0 | — | rural | yes | — | Yes | — | 200 | 0 | 0 | 0 | 6.0 | — | 140.0 | gi | 10.0 | 90.0 | 15.0 | 17.0 | 0.0 | 0.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 30 | 0 | 0 | no | — | — | Submersible Pump | Grundfos | 20.0 | 133.0 | Generator | Aska | 40.0 | — | — | — | Very good supply system condition | no | — | 29.0 | 7.72 | 2800.0 | 2050.0 | — | Private/Individual | — | — | — | — | no | — | no | — | — | — | — | 20/03/2018 | — | — | — | — |
8016 | — | Borehole | Somaliland MoWRD | April 18, 2022 | Sanaag | ceerigaabo | Ceerigaabo | 6.0 | GTZ | 18/04/2019 | GTZ1 Cerigabo borehole | — | 10.6362303 | 47.3643228 | 1800.0 | — | 1 | — | rural urban | yes | — | Yes | — | 200 | 20 | 100 | 400 | 5.0 | — | 130.0 | gi | 8.0 | — | 0.0 | 24.0 | 0.0 | 0.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 25.0 | Galvanised Steel | 5000.0 | 1 | 0 | 1 | yes | 20 | 10.0 | Submersible Pump | Luwara | 0.0 | 8.0 | Hybrid - Solar/Generator | Barking | 45.0 | 0 | 0.0 | good | 1. Good water supply. | no | — | 26.0 | 7.1 | 1600.0 | 1900.0 | — | Communal | no | — | — | — | no | — | no | — | — | — | — | — | 0 | 0 | — | — |
8050 | — | Borehole | Somaliland MoWRD | April 16, 2022 | Sool | xudun | Gobley | 11.0 | ISRC | 16/04/2022 | Gobley bore hole | — | 9.2020354 | 47.5386746 | 673.0 | — | 1 | — | urban rural | yes | — | Yes | — | 6000 | 500 | 0 | 100000 | 1.0 | — | 300.0 | pvc | 8.0 | 200.0 | 13.0 | 8.0 | 11.0 | 0.5 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 30.0 | Stainless Steel | 11000.0 | 1 | 3 | 3 | yes | 10 | 10.0 | Submersible Pump | Grundfoce | 15.0 | 220.0 | Hybrid - Solar/Generator | Barking | 45.0 | 1 | 572370.0 | good | The water supply system is good condition. | no | — | 34.0 | 7.2 | 1400.0 | 1000.0 | — | Communal | yes | 15/02/2018 | 7 | 0 | no | — | no | — | — | — | Oxfam GB | 16/03/2019 | 1.Solar installation 2.Extension of water supply | 1. Replacement of pipea 500 m 2. New water tank installation. | — | — |
SWALIM is a multi-donor project managed by FAO and currently funded by The European Union, USAID, SDC, FCDO and Government of France