Code |
BHNGBU004 |
Water Source Type |
Borehole |
Inspecting Agency |
Puntland_PWDA |
Inspection Date |
Oct. 26, 2019 |
District |
Burtinle |
Settlement Name |
Burtinle |
Settlement Distance |
0.2 |
Establishing Agency |
EFAT |
Establishing Date |
30-10-05 |
Source Name |
Burtinle BH2 |
Geometry |
None |
Latitude |
7.6278 |
Longitude |
47.8278 |
Sources Cluster |
1 |
Water Source Photo |
 |
Users |
Rural Urban |
Permanent? |
Yes |
Months Used |
None |
Functioning? |
Yes |
Non Function Reason |
None |
No of Humans |
None |
No of Camels |
1000 |
No of Cattle |
0 |
No of Shoats |
2000 |
Irrigation Area |
None |
Source Protected? |
None |
Borehole Depth |
345.0 |
Wellcasing Type |
None |
Wellcasing Size |
None |
Borehole SWL |
None |
Borehole Operating Yield |
3.0 |
Borehole Operating Hours |
None |
Borehole Operating Drawn |
None |
Borehole Recovery Time |
None |
Reservoir Type |
Other |
Reservoir Capacity |
20.0 |
Pipeline Type |
Other |
Pipeline Length |
0.0 |
HouseHold Connections |
0 |
Water Point Kiosks |
1 |
Troughs |
2 |
Source Emergency? |
Yes |
No of Trucks |
3 |
Truck Capacity |
6.0 |
Pump Type |
Submersible Pump |
Pump Model |
Lowara 15kW |
Pump Capacity |
None |
Pump Level |
336.0 |
Power Source |
Generator |
Generator Type |
Dk51280 |
Generator Capacity |
60.0 |
Solar Type |
None |
Solar Capacity |
None |
Supply Condition |
Poor |
Supply System Condition Notes |
Elevated water tank |
Physical Water Issues |
No |
Physical Problem Reason |
None |
Temperature |
28.0 |
pH |
None |
Electrical Conductivity |
3600.0 |
Total Dissolved Solids |
1840.0 |
Water Sample Code |
No Document |
Management Type |
Communal |
WSC |
None |
WSC Established Date |
None |
WSC Male |
None |
WSC Female |
None |
Humans Charged for Water? |
Yes |
Cost Of Water for Humans |
0.03 |
Water Charged for Animals? |
Yes |
Cost Of Water for Animals |
None |
Last Intervention Agency |
IR - Islamic Relief Somalia/Concern Worldwide Somalia |
Last Intervention Description |
Repair GI pipe |
Last Intervention Date |
May 25, 2016 |
Proposed Intervention Description |
Borehole development and cleaning, GI Pipe, Elevated tank 20m cube, full rehabilitation. Solar system. |
Additional Notes |
None |
Metadata Tag |
Strategic Water Sources Survey – WSS_NAT |
History |
watersource.HistoricalWaterSource.None |