Code |
BHSLCA003 |
Water Source Type |
Borehole |
Inspecting Agency |
Somaliland_MoWRD |
Inspection Date |
Nov. 6, 2019 |
District |
Caynabo |
Settlement Name |
Cawil cunaaye |
Settlement Distance |
0.0 |
Establishing Agency |
Private |
Establishing Date |
06-11-97 |
Source Name |
Cawil Cunaaye |
Geometry |
None |
Latitude |
8.9301 |
Longitude |
46.2202 |
Sources Cluster |
0 |
Water Source Photo |
 |
Users |
Rural |
Permanent? |
Yes |
Months Used |
None |
Functioning? |
Yes |
Non Function Reason |
None |
No of Humans |
None |
No of Camels |
100 |
No of Cattle |
0 |
No of Shoats |
500 |
Irrigation Area |
100.0 |
Source Protected? |
None |
Borehole Depth |
110.0 |
Wellcasing Type |
GI |
Wellcasing Size |
8.0 |
Borehole SWL |
40.0 |
Borehole Operating Yield |
24.0 |
Borehole Operating Hours |
6.0 |
Borehole Operating Drawn |
None |
Borehole Recovery Time |
None |
Reservoir Type |
Concrete/Masonry tank |
Reservoir Capacity |
24.0 |
Pipeline Type |
Galvanised Steel |
Pipeline Length |
100.0 |
HouseHold Connections |
0 |
Water Point Kiosks |
6 |
Troughs |
3 |
Source Emergency? |
Yes |
No of Trucks |
5 |
Truck Capacity |
9.0 |
Pump Type |
Submersible Pump |
Pump Model |
Grundfos |
Pump Capacity |
11.0 |
Pump Level |
54.0 |
Power Source |
Hybrid - Solar/Generator |
Generator Type |
Perkins |
Generator Capacity |
45.0 |
Solar Type |
Photovoltaic |
Solar Capacity |
16.8 |
Supply Condition |
Good |
Supply System Condition Notes |
None |
Physical Water Issues |
No |
Physical Problem Reason |
None |
Temperature |
28.0 |
pH |
8.05 |
Electrical Conductivity |
3410.0 |
Total Dissolved Solids |
2370.0 |
Water Sample Code |
No Document |
Management Type |
Private/Individual |
WSC |
None |
WSC Established Date |
None |
WSC Male |
None |
WSC Female |
None |
Humans Charged for Water? |
No |
Cost Of Water for Humans |
None |
Water Charged for Animals? |
No |
Cost Of Water for Animals |
None |
Last Intervention Agency |
Oxfam Novib |
Last Intervention Description |
Solar installation
Generator
Storage tank |
Last Intervention Date |
Aug. 6, 2018 |
Proposed Intervention Description |
Replacement of riser pipes
Replacement of water pump |
Additional Notes |
None |
Metadata Tag |
Strategic Water Sources Survey – WSS_NAT |
History |
watersource.HistoricalWaterSource.None |