Id | Code | Select the type of water source being inspected | Select the agency inspecting this water source | Enter the date of source inspection | Region | District | Enter the name of settlement / village where the source is located | Distance to nearest settlement (KM) | Select the agency that established this water source | Enter the date when the source was established | Enter the water source name | Source gpspoint | Enter water source Latitude in decimal degrees | Enter water source Longitude in decimal degrees | Enter Elevation (m.a.s.l) | Enter GPS Precision (m) | Enter number of water sources in a cluster | Water Source Photographs | Select the category of users for this water source | Is this a permanent status water source? | For how many months in a year is this water source in use (#)? | Is this water source currently functioning? | Non functioning reason | No. of persons using | No. of Camels using the source | No. of Cattle using the source | No. of Sheep/Goats using the source | Area irrigated using the source (ha) | Is the source protected? | What is the depth of this borehole (m)? | Type of Casing | Casing size (inches) | What is the current static water level of this borehole (m)? | What is the yield of this borehole (m3/hr)? | How long is this borehole operated in a day (hr)? | What is the borehole draw down (m)? | After pumping, how long does this borehole take to recover (hr)? | What is the depth of this dug well (m)? | What is the current static water level of this dug well (m)? | What is the yield of this dug well (m3/hr)? | How long is this dug well operated in a day (hr)? | What is the dug well draw down (m)? | After pumping, how long does this dug well take to recover (hr)? | What is the depth of this dam (m)? | What is the length of this dam (m)? | What is the width of this dam (m)? | What is the depth of this berkad (m)? | What is the length of this berkad (m)? | What is the width of this berkad (m)? | What is the cumulative discharge rate of this spring (m3/hr)? | What is the depth of this source (m)? | What is the length of this source (m)? | What is the width of this source (m)? | What is the yield of the source (m3/hr)? | What type of reservoir is used for this source? | Reservoir capacity (m3) | Pipeline type | Pipeline length (m) | How many House Holds (HH) are connected to this water source? | How many kiosks/water points are connected to this source? | How many animal troughs are connected to this source? | Source used for water trucking during emergency? | No. of trucks / day | Average truck capacity (m3) | Pump type | Pump model | Pump capacity (m3/hr) | Pump level (m) | Power source | Generator/Solar type | Generator capacity (kVA/kWh) | What type/model is the solar used? | What capacity is the solar (kWh)? | Condition of supply system | Additional notes on supply & distribution system condition | Any visible physical problem (color, odor)? | Please describe the color, odor and smell of water | Temperature | PH | Electrical Conductivity (µs/cm) | Total Dissolved Solids (mg/l) | Water sample code. (if taken) | Management type | Water & Sanitation Committee (WSC)? | Year established | WSC members male | WSC members female | DIs water for human use charged? | Current cost of 20 ltr jerrican (USD/20ltr) | Is water for animal use charged? | Current cost for Livestock (USD/100ltr) | What is the name of the operator/caretaker for this water source? | What is the phone number of the operator/caretaker? | Which agency carried out last intervention on this water source? | Recent interventions | Last intervention date | Proposed intervention description | Additional Notes | Metadata Tag |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1902 | BHTGBC135 | Borehole | Somaliland_MoWR | Jan. 5, 2014 | Togdheer | Burco | Aden Suleiman | — | UAERC - United Arab Emirates Red Crescent | 01-01-12 | Aden Suleiman | — | 9.52503 | 45.5957 | 1016.0 | — | — | — | Urban | Yes | — | Yes | — | — | — | — | — | 6.0 | — | 160.0 | — | — | 100.0 | 18.0 | 1.0 | 4.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 10.0 | — | 120.0 | — | — | — | — | — | — | — | Lowara 11kW | — | — | — | — | — | — | — | — | — | — | — | — | 7.3 | 12030.0 | 8030.0 | — | Public | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Strategic Boreholes Survey – BHS |
4844 | DWSNCR081 | Dug Well | SWALIM_HGS | Feb. 18, 2012 | Sanaag | Ceerigaabo | — | — | — | — | Darbi-Duqa | — | 10.6685 | 47.5922 | 1532.0 | — | — | — | — | — | — | Yes | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 6.1 | 4.5 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 8.1 | 3760.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Taleh formation | Hydrogeological Survey and Assessment of Selected Areas in Somaliland and Puntland - HASP |
1860 | BHTGBC094 | Borehole | Somaliland_MoWR | Jan. 7, 2014 | Togdheer | Burco | Ternary Factory Area | — | Tannery Factory | 01-06-01 | Ternary Factory | — | 9.5172 | 45.5518 | 1036.0 | — | — | — | Urban | Yes | — | Yes | — | — | — | — | — | — | — | 160.0 | — | — | 115.0 | 20.0 | 1.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 84.0 | — | 250.0 | — | — | — | — | — | — | — | Franklin 25kW | — | 138.0 | — | — | — | — | — | — | — | — | — | — | 7.8 | 3580.0 | 2360.0 | — | Private | — | — | — | — | — | — | — | — | — | — | Tannery Factory | Pipe maintenance 60m | 2012-05-01 | — | — | Strategic Boreholes Survey – BHS |
1906 | BHTGBC139 | Borehole | Somaliland_MoWR | Feb. 1, 2014 | Togdheer | Burco | Ilays Factory Area | — | Ali shaybe (Owner) | 01-06-04 | Shaybe Ali BH2 | — | 9.4865 | 45.5994 | 1015.0 | — | — | — | Rural | Yes | — | Yes | — | — | — | — | — | 10.0 | — | 120.0 | — | — | 100.0 | 7.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 10.0 | — | 200.0 | — | — | — | — | — | — | — | Grundfos 7.5 | — | 115.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Private | — | — | — | — | — | — | — | — | — | — | Alishay the ( Owner) | New generator installed | — | — | — | Strategic Boreholes Survey – BHS |
1911 | BHTGBC143 | Borehole | Somaliland_MoWR | Jan. 30, 2014 | Togdheer | Burco | I lays Factory Area | — | — | — | Suleiman Ninmadow | — | 9.4845 | 45.6012 | 1014.0 | — | — | — | Rural | Yes | — | No | — | — | — | — | — | — | — | 120.0 | — | — | 100.0 | 7.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Grundfos 7.5kW | — | 115.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Private | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Strategic Boreholes Survey – BHS |
4980 | DWTGBC016 | Dug Well | SWALIM_WSIS | June 18, 2008 | Togdheer | Burco | Harradda Gubato Xil | — | — | — | Harrada Gubato Xil | — | 8.7789 | 45.4641 | 817.0 | — | — | — | — | Yes | — | Yes | — | — | 800 | — | 4500 | — | — | — | — | — | — | — | — | — | — | 9.0 | 5.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 7.5 | 306.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Improve | — | Water Sources Inventory Survey – WSIS |
1916 | BHTGBC148 | Borehole | Somaliland_MoWR | Jan. 30, 2014 | Togdheer | Burco | Aden Suleiman | — | Mahamed Jana Galal ( Owner) | 01-01-14 | Mahamed Jama Galal | — | 9.5071 | 45.6063 | 1009.0 | — | — | — | Rural | Yes | — | Yes | — | 2 | 10 | — | — | 40.0 | — | 100.0 | — | — | 25.0 | 12.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 12.0 | — | 100.0 | — | — | — | — | — | — | — | Lowara / Franklin 7.5kW | — | 97.0 | — | — | — | — | — | — | — | — | — | — | 7.5 | 9510.0 | 6360.0 | — | Private | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Strategic Boreholes Survey – BHS |
1918 | BHTGBC150 | Borehole | Somaliland_MoWR | Jan. 30, 2014 | Togdheer | Burco | Kurta Siibakhti | — | Mahamed Curyan | 01-06-07 | Deero Company | — | 9.5133 | 45.6338 | 1001.0 | — | — | — | Rural | Yes | — | No | — | — | — | — | — | — | — | 100.0 | — | — | 30.0 | 5.0 | 10.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Lowara 2.2kW | — | 97.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Private | — | — | — | — | — | — | — | — | — | — | Deero Company | Solar system | 2013-07-05 | — | — | Strategic Boreholes Survey – BHS |
2788 | DWBKWA036 | Dug Well | SWALIM Archives | July 12, 2004 | Bakool | Waajid | — | 8.0 | — | 28-04-05 | Kawi | — | 3.7838 | 43.308 | 404.0 | — | — | — | — | No | — | Yes | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 2.0 | 37.0 | 17.0 | — | — | — | — | — | — | — | — | — | 1258.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Community | Yes | — | — | — | — | — | — | — | No | — | — | — | 2005-06-26 | — | from Dams file | Water Sources Data from Partners – WSD_Pat |
4839 | DWSNCR076 | Dug Well | SWALIM_HGS | Feb. 18, 2012 | Sanaag | Ceerigaabo | — | — | — | — | Daray 3 | — | 10.6693 | 47.5068 | 1672.0 | — | — | — | — | — | — | Yes | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 7.5 | 7.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 7.9 | 3720.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Taleh formation | Hydrogeological Survey and Assessment of Selected Areas in Somaliland and Puntland - HASP |