Id | Code | Select the type of water source being inspected | Select the agency inspecting this water source | Enter the date of source inspection | Region | District | Enter the name of settlement / village where the source is located | Distance to nearest settlement (KM) | Select the agency that established this water source | Enter the date when the source was established | Enter the water source name | Source gpspoint | Enter water source Latitude in decimal degrees | Enter water source Longitude in decimal degrees | Enter Elevation (m.a.s.l) | Enter GPS Precision (m) | Enter number of water sources in a cluster | Water Source Photographs | Select the category of users for this water source | Is this a permanent status water source? | For how many months in a year is this water source in use (#)? | Is this water source currently functioning? | Non functioning reason | No. of persons using | No. of Camels using the source | No. of Cattle using the source | No. of Sheep/Goats using the source | Area irrigated using the source (ha) | Is the source protected? | What is the depth of this borehole (m)? | Type of Casing | Casing size (inches) | What is the current static water level of this borehole (m)? | What is the yield of this borehole (m3/hr)? | How long is this borehole operated in a day (hr)? | What is the borehole draw down (m)? | After pumping, how long does this borehole take to recover (hr)? | What is the depth of this dug well (m)? | What is the current static water level of this dug well (m)? | What is the yield of this dug well (m3/hr)? | How long is this dug well operated in a day (hr)? | What is the dug well draw down (m)? | After pumping, how long does this dug well take to recover (hr)? | What is the depth of this dam (m)? | What is the length of this dam (m)? | What is the width of this dam (m)? | What is the depth of this berkad (m)? | What is the length of this berkad (m)? | What is the width of this berkad (m)? | What is the cumulative discharge rate of this spring (m3/hr)? | What is the depth of this source (m)? | What is the length of this source (m)? | What is the width of this source (m)? | What is the yield of the source (m3/hr)? | What type of reservoir is used for this source? | Reservoir capacity (m3) | Pipeline type | Pipeline length (m) | How many House Holds (HH) are connected to this water source? | How many kiosks/water points are connected to this source? | How many animal troughs are connected to this source? | Source used for water trucking during emergency? | No. of trucks / day | Average truck capacity (m3) | Pump type | Pump model | Pump capacity (m3/hr) | Pump level (m) | Power source | Generator/Solar type | Generator capacity (kVA/kWh) | What type/model is the solar used? | What capacity is the solar (kWh)? | Condition of supply system | Additional notes on supply & distribution system condition | Any visible physical problem (color, odor)? | Please describe the color, odor and smell of water | Temperature | PH | Electrical Conductivity (µs/cm) | Total Dissolved Solids (mg/l) | Water sample code. (if taken) | Management type | Water & Sanitation Committee (WSC)? | Year established | WSC members male | WSC members female | DIs water for human use charged? | Current cost of 20 ltr jerrican (USD/20ltr) | Is water for animal use charged? | Current cost for Livestock (USD/100ltr) | What is the name of the operator/caretaker for this water source? | What is the phone number of the operator/caretaker? | Which agency carried out last intervention on this water source? | Recent interventions | Last intervention date | Proposed intervention description | Additional Notes | Metadata Tag |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2656 | DWBDWR001 | Dug Well | FGS_MoEWR | Jan. 1, 2019 | Banadir | Warta Nabada | Waaxda 2aad Hantiwadaag | — | Private | 1/1/1990 | Ceelka Marshaale | — | 2.0446 | 45.3302 | 29.0 | — | — | — | Human | Yes | — | Yes | — | 2400 | — | — | — | — | Yes | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Submersible_pump | — | — | — | — | Good | — | — | Clear | 29.0 | 7.3 | 259.0 | 2550.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Strategic Water Sources Survey in Banadir Region – WSS_BA |
7307 | — | Borehole | Galmudug Ministry of Energy and Water Resources | April 11, 2022 | Mudug | galkayo | laasacadale | 1.4 | — | — | laasacadale Borehole | — | 6.60527 | 47.4200867 | 299.0 | — | 0 | — | rural | yes | — | Yes | — | 2400 | 10780 | — | 85900 | — | — | 180.0 | pvc | 8.0 | — | 10.0 | 14.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 50.0 | Galvanised Steel | 98.0 | 0 | 1 | 3 | yes | 15 | 10.0 | Submersible Pump | grunfos | — | 86.0 | Hybrid - Solar/Generator | Doutz | 32.0 | 340w | 20.0 | poor | not have water disribtion pipes | no | — | 30.8 | 7.72 | 785.0 | 546.0 | — | Communal | — | — | — | — | yes | 0.001 | yes | — | — | — | IOM | solar | — | 2021-07-11 | — | — |
4044 | DWMSBA002 | Dug Well | FGS_MoEWR | Oct. 3, 2019 | Middle Shabelle | balcad | WarSheikh | — | Community | 2/9/2010 | Shawtali - Ceel Macaan - DW | — | 2.1787 | 45.5944 | 7.0 | — | 2 | 1571158650111.jpg | — | yes | — | Yes | — | 2400 | 540 | 350 | 9500 | 0.0 | No | — | — | — | — | — | — | — | — | 18.0 | 10.0 | — | 12.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | — | Galvanised Steel | 20.0 | 0 | 1 | 3 | no | — | — | — | F6 | 8.0 | 16.0 | Submersible Pump | Dose | 15.0 | — | — | — | — | No | — | 30.8 | 8.1 | 1340.0 | 630.0 | — | — | Yes | 3/9/2018 | 4 | 1 | No | — | No | — | — | — | — | — | — | Solar system, large tanks, pipelines, pumps and full rehabilitation. | — | Strategic Water Sources Survey – WSS_NATl |
1510 | BHNGGA061 | Borehole | SWALIM_HGS | Feb. 4, 2012 | Nugaal | Garoowe | — | — | — | — | Libaaxo/LIB057 | — | 8.59923 | 49.18963 | 458.0 | — | — | — | — | — | — | — | — | 2400 | — | — | 600 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 27.0 | 8.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 1989-04-11 | — | Quarterian | Hydrogeological Survey and Assessment of Selected Areas in Somaliland and Puntland - HASP |
7156 | — | Borehole | Somaliland MoWRD | March 31, 2022 | Togdheer | buuhoodle | Qabri Hulul | 0.2 | IR | 01/01/2016 | Qabri Hull borehole | — | 8.685275 | 46.2782063 | 832.0 | — | 1 | — | rural | yes | — | Yes | — | 2400 | 400 | 0 | 2800 | 0.0 | — | 333.0 | pvc | 8.0 | 270.0 | 15.0 | 2.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 40.0 | Galvanised Steel | 25.0 | 400 | 1 | 8 | yes | 4 | 8.0 | Submersible Pump | Luara | 15.0 | 300.0 | Hybrid - Solar/Generator | JP45 | 45.0 | GPM300 | 300.0 | good | The condition of the solar system and has spare parts | no | — | 36.0 | 7.3 | 1000.0 | 394.0 | — | Communal | no | — | — | — | no | — | yes | — | — | — | IR | 01/02/2016 | Construction of new borehole | Rehabilitation of reservoirs and animal trough installation | — | — |
3289 | DWGDDO002 | Dug Well | FGS_MoEWR | Oct. 4, 2019 | Gedo | Doolow | Malkaarey | — | ADRA - Adventist Development Relief Agency | 4/29/2013 | Ukure | — | 3.9872 | 41.9118 | 196.0 | 4.4 | — | 1571137034174.jpg | — | yes | — | Yes | — | 2380 | — | — | — | — | Yes | — | — | — | — | — | — | — | — | 9.0 | 5.0 | 48.0 | 12.0 | 1.0 | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | — | Stainless Steel | 100.0 | 340 | 7 | — | no | — | — | — | Grundfos | 48.0 | 7.0 | Submersible Pump | — | — | Chinaland | 3.5 | — | — | No | — | 31.7 | 7.5 | 390.0 | 190.0 | — | — | — | — | — | — | No | — | — | — | — | — | — | Depth extension, installed Solar System 14 pannel 250W, submersible pump7.5, Concrete water tank rehabilitation, And constructing three kiosks | 2019-06-09 | Depth extension, solar system14 pannel 250w. And 5 kiosks | — | Strategic Water Sources Survey – WSS_NATl |
1136 | BHMDGK024 | Borehole | Puntland_PSAWEN | Jan. 4, 2014 | Mudug | Galkacyo | Halabooqad | — | WDA | 01-06-73 | Halabooqad | — | 6.8543 | 47.4135 | 302.0 | — | — | — | Urban | Yes | — | Yes | — | 2300 | 500 | 40 | 1000 | 0.25 | — | 180.0 | — | — | 90.0 | 12.0 | 8.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 80.0 | — | 1200.0 | — | — | — | — | — | — | Submersible Pump | Lowara 11kW | — | 150.0 | — | — | — | — | — | — | — | — | — | — | 7.8 | 7003.0 | 3052.0 | — | Public | — | — | — | — | — | 0.05 | — | 0.2 | — | — | CARE Somalia | Water Tank and Generator Room | 2012-07-04 | New Generator 40Kva and Pipeline 800m | — | Strategic Boreholes Survey – BHS |
2282 | BHWGHA175 | Borehole | SWALIM_HGS | Dec. 31, 2011 | Woqooyi Galbeed | — | waalid xoor | 7.8 | — | — | Waalid xoor | — | 9.38698 | 43.51351 | 1454.0 | — | — | — | — | — | — | Yes | — | 2300 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 2008-10-15 | — | — | Hydrogeological Survey and Assessment of Selected Areas in Somaliland and Puntland - HASP |
3802 | DWLSWA001 | Dug Well | FGS_MoEWR | Oct. 15, 2019 | Lower Shabelle | Wanla Weyn | Warta Da'ud Buule | — | Jimciyada Tadaman al islam | 2/10/2014 | Ibnu Mubarag BH | — | 2.616 | 44.8845 | 90.0 | 4.288 | 0 | — | — | yes | — | Yes | — | 2250 | — | — | — | — | No | — | — | — | — | — | — | — | — | — | — | 18.0 | 10.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | — | PVC | 1500.0 | 300 | 0 | 0 | yes | 2 | 15.0 | — | Caprari | 20.0 | 120.0 | Submersible Pump | Gangfa | 24.0 | — | — | — | — | No | — | 30.7 | 7.3 | 1500.0 | 760.0 | — | — | Yes | 10/14/2015 | 5 | 0 | Yes | 0.025 | No | — | — | — | — | — | — | Rehabilitation of water tank, new large water tanks, Solar system, pump with pipes, stores, and well head protection. | — | Strategic Water Sources Survey – WSS_NATl |
7301 | — | Dug Well | Somaliland MoWRD | May 9, 2022 | Awdal | borama | Carro weyn | — | — | — | Carro-weyn dug well | — | 10.2770499 | 43.4122033 | 854.0 | — | — | — | urban rural | yes | — | Yes | — | 2200 | 3000 | — | 5000 | — | — | — | — | — | — | — | — | — | — | 8.0 | 4.0 | 1.0 | 8.0 | 3.0 | — | — | — | — | — | — | — | — | — | — | — | — | Plastic tank | 2.0 | PVC | 150.0 | 215 | 1 | 1 | no | — | — | Submersible Pump | — | 1.0 | 7.0 | Solar | — | — | Axitec | 1.2 | fair | The pipelines is connected to the reservoir. | no | — | 35.0 | 7.8 | 412.0 | 290.0 | — | Communal | no | — | — | — | yes | 0.02 | yes | — | — | — | — | — | — | Reservoir rehabilitation, solar panel extension, and increasing the depth of the dugwell. | — | — |
SWALIM is a multi-donor project managed by FAO and currently funded by The European Union, USAID, SDC, FCDO and Government of France