Id | Code | Select the type of water source being inspected | Select the agency inspecting this water source | Enter the date of source inspection | Region | District | Enter the name of settlement / village where the source is located | Distance to nearest settlement (KM) | Select the agency that established this water source | Enter the date when the source was established | Enter the water source name | Source gpspoint | Enter water source Latitude in decimal degrees | Enter water source Longitude in decimal degrees | Enter Elevation (m.a.s.l) | Enter GPS Precision (m) | Enter number of water sources in a cluster | Water Source Photographs | Select the category of users for this water source | Is this a permanent status water source? | For how many months in a year is this water source in use (#)? | Is this water source currently functioning? | Non functioning reason | No. of persons using | No. of Camels using the source | No. of Cattle using the source | No. of Sheep/Goats using the source | Area irrigated using the source (ha) | Is the source protected? | What is the depth of this borehole (m)? | Type of Casing | Casing size (inches) | What is the current static water level of this borehole (m)? | What is the yield of this borehole (m3/hr)? | How long is this borehole operated in a day (hr)? | What is the borehole draw down (m)? | After pumping, how long does this borehole take to recover (hr)? | What is the depth of this dug well (m)? | What is the current static water level of this dug well (m)? | What is the yield of this dug well (m3/hr)? | How long is this dug well operated in a day (hr)? | What is the dug well draw down (m)? | After pumping, how long does this dug well take to recover (hr)? | What is the depth of this dam (m)? | What is the length of this dam (m)? | What is the width of this dam (m)? | What is the depth of this berkad (m)? | What is the length of this berkad (m)? | What is the width of this berkad (m)? | What is the cumulative discharge rate of this spring (m3/hr)? | What is the depth of this source (m)? | What is the length of this source (m)? | What is the width of this source (m)? | What is the yield of the source (m3/hr)? | What type of reservoir is used for this source? | Reservoir capacity (m3) | Pipeline type | Pipeline length (m) | How many House Holds (HH) are connected to this water source? | How many kiosks/water points are connected to this source? | How many animal troughs are connected to this source? | Source used for water trucking during emergency? | No. of trucks / day | Average truck capacity (m3) | Pump type | Pump model | Pump capacity (m3/hr) | Pump level (m) | Power source | Generator/Solar type | Generator capacity (kVA/kWh) | What type/model is the solar used? | What capacity is the solar (kWh)? | Condition of supply system | Additional notes on supply & distribution system condition | Any visible physical problem (color, odor)? | Please describe the color, odor and smell of water | Temperature | PH | Electrical Conductivity (µs/cm) | Total Dissolved Solids (mg/l) | Water sample code. (if taken) | Management type | Water & Sanitation Committee (WSC)? | Year established | WSC members male | WSC members female | DIs water for human use charged? | Current cost of 20 ltr jerrican (USD/20ltr) | Is water for animal use charged? | Current cost for Livestock (USD/100ltr) | What is the name of the operator/caretaker for this water source? | What is the phone number of the operator/caretaker? | Which agency carried out last intervention on this water source? | Recent interventions | Last intervention date | Proposed intervention description | Additional Notes | Metadata Tag |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
8655 | — | Dug Well | FGS Ministry of Energy and Water Resources | March 19, 2022 | Bay | bur_hakaba | Reebey | 8.0 | GREDO | 19/01/2020 | Fanqal | — | 0 | 0 | — | — | 3 | — | rural | no | 12 | Yes | — | 340 | 60 | 154 | 254 | 1.0 | — | — | — | — | — | — | — | — | — | 35.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Other | — | Other | — | — | — | — | no | — | — | No Pump | — | — | — | — | — | — | — | — | fair | — | no | — | — | — | — | — | — | Private-Public-Partnership | — | — | — | — | no | — | no | — | — | — | — | — | — | — | — | — |
7451 | — | Dug Well | FGS Ministry of Energy and Water Resources | March 16, 2022 | Hiraan | beled_weyne | Bundoweyn IDPS | 2.0 | Community | 10/10/2002 | Midaam | — | 4.734971 | 45.2066398 | 153.0 | — | 5 | — | urban | yes | — | Yes | — | 3920 | — | — | — | — | — | — | — | — | — | — | — | — | — | 15.0 | 10.0 | 8.0 | 4.0 | 6.0 | 2.0 | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 10.0 | PVC | 1200.0 | 563 | 0 | 0 | no | — | — | Surface mounted Pump | Dynamos | 8.0 | — | Generator | Changfa | 12.0 | — | — | good | Ok | no | — | — | — | — | — | — | Private/Individual | — | — | — | — | yes | 0.1 | no | — | — | — | RI | 15-Nov-20 | Generator | Elevator water tanker l, solar, PVC | — | — |
7424 | — | Dug Well | Somaliland MoWRD | April 16, 2022 | Woqooyi Galbeed | hargeisa | Cadaadley district | 0.1 | UNICEF | 15/05/1991 | Cadaadley Dug well | — | 9.7682462 | 44.6896322 | 1245.0 | — | 20 | — | rural urban | yes | — | Yes | — | 2000 | 100 | 0 | 1500 | 0.0 | — | — | — | — | — | — | — | — | — | 4.0 | 3.0 | 3.0 | 6.6 | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 25.0 | Galvanised Steel | 500.0 | 300 | 3 | 0 | no | — | — | Submersible Pump | Capriri | 6.0 | 3.0 | Hybrid - Solar/Generator | Yanmer | 7.0 | — | 1.3 | poor | Very poor becouse of the pump and pipe and also droughts. | no | — | 29.0 | 7.6 | 1322.0 | 927.0 | — | Communal | no | — | — | — | yes | 0.12 | no | — | — | — | — | 11/07/2008 | Engine rehapilitation, solar instalation. | New dug well | — | — |
8665 | — | Borehole | FGS Ministry of Energy and Water Resources | — | Bay | Baydhaba | Boonkaay | — | UNICEF - United Nations Children's Fund | 1/1/2009 | Bonkaay BH2 | — | 3.1517 | 43.6282 | — | — | — | — | — | Yes | — | Yes | — | — | — | — | — | — | — | 120.0 | — | — | 16.0 | 16.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Community | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
7074 | — | Borehole | Puntland Ministry of Energy Minerals and Water | Feb. 19, 2022 | Bari | qardho | Dangorayo | 1.0 | TASS | 18/01/2007 | Dangorayo borehole | — | 8.7252347 | 49.3311253 | 585.0 | — | 1 | — | rural urban | yes | — | No | 12/2/2022 the day stopped functioning. Main raising pipes requires changing. | 9600 | 2000 | 0 | 5000 | 1.0 | — | 412.0 | pvc | 8.0 | 210.0 | 12.0 | 9.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 100.0 | Galvanised Steel | 1000.0 | 1600 | 0 | 2 | yes | 5 | 9.0 | Submersible Pump | Lawara | — | 250.0 | Hybrid - Solar/Generator | Perkins | 60.0 | 300-72M | 27.0 | good | Pump conditionis is good, Condition of the pipelines are good. elevated water tank is intact. | no | — | — | — | — | — | — | Communal | yes | 01/01/2022 | 10 | 0 | yes | 0 | yes | — | — | — | NRC | 28/05/2021 | Replacement of main raising pipe. | Replacement of the main raising pipes. | — | — |
7425 | — | Dug Well | Puntland Ministry of Energy Minerals and Water | March 19, 2022 | Bari | iskushuban | Xaafuun | 6.0 | Community_ | 19/09/2005 | Mutakiini 1 | — | 10.4381589 | 51.2515067 | -18.0 | — | 3 | — | rural urban | yes | — | Yes | — | 1500 | 200 | — | 2000 | — | — | — | — | — | — | — | — | — | — | 11.0 | 10.0 | 0.5 | 6.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 18.0 | PVC | — | 4 | 8 | — | no | — | — | Submersible Pump | Lowara | — | 10.0 | Hybrid - Solar/Generator | FG wilson | 33.0 | JCNS-M36V360W | 2.16 | poor | The yield is very low. Both dug well distribute water to 1 elevated water tank. | no | — | 27.8 | 9.0 | 3250.0 | 1624.0 | — | Communal | yes | — | 4 | 3 | yes | 0.1 | no | — | — | — | Puntland MoEMW | 20/08/2012 | 1: Installation of solar power system. 2: Supplied generator | 1: Replacement of main raising pipes and submersible pump. 2: Digging the deep of the well in order to increase yield. 3: Construction of animal troughs. | — | — |
7447 | — | Dug Well | FGS Ministry of Energy and Water Resources | March 29, 2022 | Lower Shabelle | afgooye | Aaytiro | 2.0 | Community | 29/03/2020 | Ibnu Maxamed water supply | — | 2.1470624 | 45.1183974 | 53.0 | — | 1 | — | rural | yes | — | Yes | — | 1260 | 0 | 0 | 0 | 0.0 | — | — | — | — | — | — | — | — | — | 14.0 | 5.0 | 21.0 | 24.0 | 3.0 | 1.0 | — | — | — | — | — | — | — | — | — | — | — | Plastic tank | 3.0 | PVC | 1.0 | 180 | 1 | 0 | yes | 2 | 6.0 | Submersible Pump | 3.5 - 4 Italian | 4.0 | 2.0 | Generator | Gencava 150 | 5.0 | — | — | good | Distribution of families who live in the area | no | — | 0.0 | — | — | — | — | Communal | yes | 29-Jun-21 | 3 | 2 | yes | 0.1 | no | — | — | — | Community | 1-Jan-22 | Pipeline and pump repair | Excavation of the depth, construction of new water tank, New generator and pump. Design for solar system for future | — | — |
7783 | — | Dug Well | FGS Ministry of Energy and Water Resources | May 29, 2022 | Hiraan | beled_weyne | Shabellow | — | — | 22/07/2013 | Shabellow | — | 4.753113 | 45.2163659 | — | — | 2 | — | urban | yes | — | Yes | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 6.0 | 4.0 | 0.5 | 7.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Hand Pump | — | — | — | — | — | — | — | — | fair | — | no | — | 33.2 | 6.89 | 7610.0 | 4790.0 | — | Communal | — | — | — | — | no | — | — | — | — | — | — | — | — | Deepening | — | — |
7426 | — | Dug Well | Puntland Ministry of Energy Minerals and Water | March 19, 2022 | Bari | iskushuban | Xaafun | 6.0 | Save the children | 22/06/2015 | Matakiini 2 | — | 10.4353928 | 51.2490906 | -37.0 | — | 3 | — | rural urban | yes | — | Yes | — | 1500 | 200 | — | 2500 | — | — | — | — | — | — | — | — | — | — | 8.0 | 7.0 | 1.0 | 6.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 18.0 | PVC | — | 4 | 8 | 1 | no | — | — | Submersible Pump | Lowara | — | 8.0 | Solar | — | — | HE305-72P | 4.27 | poor | The yield is very low. Xaafun have two dug well, both they distribute water to 1 elevated water tank. The water tank distribute water to the kiosks in the village and animal troughs. | no | — | 27.8 | 9.0 | 3250.0 | 1624.0 | — | Communal | yes | 18/07/2021 | 4 | 3 | yes | 0.1 | no | — | — | — | CARE Somalia | 17/02/2022 | 1: Installation of solar power system. 2: Supplied submersible pump. 3: Rehabilation of elevated water tank in order to stop water leaking. 4: Rehabilitation of caretaker room | 1: Construction of another borehole. 2: Generator. 3: animal troughs. 4: Distribution pipe lines. 5: Construction of 4 kiosks in the school. | — | — |
7428 | — | Dug Well | FGS Ministry of Energy and Water Resources | May 30, 2022 | Hiraan | beled_weyne | Xaawataako | — | — | 23/12/2000 | Jaaburi | — | 4.4419 | 45.1223 | — | — | — | — | urban | yes | — | Yes | — | 1200 | — | — | — | — | — | — | — | — | — | — | — | — | — | 15.0 | 12.0 | 12.0 | 15.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | Plastic tank | 3.0 | — | — | 800 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | fair | — | no | — | 33.0 | 7.0 | 2550.0 | 1290.0 | — | Private/Individual | — | — | — | — | yes | 0.1 | — | — | — | — | — | — | — | Full Rehabilitation | — | — |
SWALIM is a multi-donor project managed by FAO and currently funded by The European Union, USAID, SDC, FCDO and Government of France