Id | Code | Select the type of water source being inspected | Select the agency inspecting this water source | Enter the date of source inspection | Region | District | Enter the name of settlement / village where the source is located | Distance to nearest settlement (KM) | Select the agency that established this water source | Enter the date when the source was established | Enter the water source name | Source gpspoint | Enter water source Latitude in decimal degrees | Enter water source Longitude in decimal degrees | Enter Elevation (m.a.s.l) | Enter GPS Precision (m) | Enter number of water sources in a cluster | Water Source Photographs | Select the category of users for this water source | Is this a permanent status water source? | For how many months in a year is this water source in use (#)? | Is this water source currently functioning? | Non functioning reason | No. of persons using | No. of Camels using the source | No. of Cattle using the source | No. of Sheep/Goats using the source | Area irrigated using the source (ha) | Is the source protected? | What is the depth of this borehole (m)? | Type of Casing | Casing size (inches) | What is the current static water level of this borehole (m)? | What is the yield of this borehole (m3/hr)? | How long is this borehole operated in a day (hr)? | What is the borehole draw down (m)? | After pumping, how long does this borehole take to recover (hr)? | What is the depth of this dug well (m)? | What is the current static water level of this dug well (m)? | What is the yield of this dug well (m3/hr)? | How long is this dug well operated in a day (hr)? | What is the dug well draw down (m)? | After pumping, how long does this dug well take to recover (hr)? | What is the depth of this dam (m)? | What is the length of this dam (m)? | What is the width of this dam (m)? | What is the depth of this berkad (m)? | What is the length of this berkad (m)? | What is the width of this berkad (m)? | What is the cumulative discharge rate of this spring (m3/hr)? | What is the depth of this source (m)? | What is the length of this source (m)? | What is the width of this source (m)? | What is the yield of the source (m3/hr)? | What type of reservoir is used for this source? | Reservoir capacity (m3) | Pipeline type | Pipeline length (m) | How many House Holds (HH) are connected to this water source? | How many kiosks/water points are connected to this source? | How many animal troughs are connected to this source? | Source used for water trucking during emergency? | No. of trucks / day | Average truck capacity (m3) | Pump type | Pump model | Pump capacity (m3/hr) | Pump level (m) | Power source | Generator/Solar type | Generator capacity (kVA/kWh) | What type/model is the solar used? | What capacity is the solar (kWh)? | Condition of supply system | Additional notes on supply & distribution system condition | Any visible physical problem (color, odor)? | Please describe the color, odor and smell of water | Temperature | PH | Electrical Conductivity (µs/cm) | Total Dissolved Solids (mg/l) | Water sample code. (if taken) | Management type | Water & Sanitation Committee (WSC)? | Year established | WSC members male | WSC members female | DIs water for human use charged? | Current cost of 20 ltr jerrican (USD/20ltr) | Is water for animal use charged? | Current cost for Livestock (USD/100ltr) | What is the name of the operator/caretaker for this water source? | What is the phone number of the operator/caretaker? | Which agency carried out last intervention on this water source? | Recent interventions | Last intervention date | Proposed intervention description | Additional Notes | Metadata Tag |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
7094 | — | Borehole | Puntland Ministry of Energy Minerals and Water | April 13, 2022 | Sanaag | laasqoray | Dhahar | 0.8 | Community_ | 01/01/2012 | Qaawane Borehole | — | 9.7419147 | 48.8105915 | 890.0 | — | 1 | — | rural urban | yes | — | No | Since March 2022 Submersible pump stopped working And the main raising pipes are rusted and leaking. | 120 | 5000 | — | 15000 | — | — | 220.0 | gi | 8.0 | — | 12.0 | 13.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 12.0 | Galvanised Steel | 190.0 | — | 1 | 3 | no | — | — | Submersible Pump | Luwara | — | 180.0 | Hybrid - Solar/Generator | Iveco | 30.0 | JCNS-M36V350W | 21.0 | poor | 1:Submersible pump has stopped working. 2:Pipes and the pipelines are leaking and also the water tank is leaking | no | — | — | — | — | — | — | Communal | — | — | — | — | no | — | yes | — | — | — | 1:Psawen 2:NRC | 01/01/2019 | PSAWEN - provided the replacement of submersible pump only. NRC- provided the solar system only. | 1:Immediate change of the submersible pump and the main raising pipes in order the borehole to function. 2: Pipeline and the water tank Rehabilitation. 3: kiosks 4: battery storage if it's possible. 5: another Larger capacity water tank. 6: secondary Generator if it's possible. | — | — |
7491 | — | Dug Well | Somaliland MoWRD | April 25, 2022 | Woqooyi Galbeed | gebiley | Arabsiyo | 0.1 | Kayse Hugur | 25/04/2021 | Kayse Hugur borehole | — | 9.6738638 | 43.7586429 | 1341.0 | — | 0 | — | urban | yes | — | Yes | — | 0 | — | — | — | — | — | — | — | — | — | — | — | — | — | 32.0 | 29.0 | 2.0 | 17.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | Other | 35.0 | — | — | 0 | 0 | 0 | yes | 18 | 10.0 | Submersible Pump | Grundfos | 5.0 | 31.0 | Electricity Grid | — | — | — | — | — | — | no | — | 27.0 | 8.1 | 420.0 | 320.0 | — | Private/Individual | — | — | — | — | yes | 0.06 | no | — | — | — | — | — | — | — | — | — |
7707 | — | Dug Well | FGS Ministry of Energy and Water Resources | May 30, 2022 | Hiraan | beled_weyne | Howlwadaag | — | Former Somali Government | 23/07/1950 | Farah Gedi | — | 4.441 | 45.1317 | — | — | — | — | urban | yes | — | Yes | — | 6000 | — | — | — | — | — | — | — | — | — | — | — | — | — | 17.0 | 10.0 | 12.0 | 18.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 12.0 | — | — | 1000 | — | — | yes | — | — | — | — | — | — | — | — | — | — | — | fair | — | no | — | 33.0 | 8.0 | 2060.0 | 1040.0 | — | Private/Individual | — | — | — | — | yes | 0.01 | — | — | — | — | — | — | — | Full Rehabilitation and supply of new generator | — | — |
8643 | — | Dug Well | FGS Ministry of Energy and Water Resources | April 19, 2022 | Bay | bur_hakaba | Waaberi | — | Agency not specified | 01/01/2010 | Waaberi | — | 2.762016 | 44.098096 | 0.0 | — | 21 | — | urban | no | — | Yes | — | 3600 | — | — | — | — | — | — | — | — | — | — | — | — | — | 30.0 | 10.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | fair | — | no | — | — | — | — | — | — | Communal | yes | — | — | — | — | — | — | — | — | — | — | — | — | Improve - Quick rehabilitation (Complete Solar system with small Pump is needed, constructing water troughs) | — | — |
7524 | — | Dug Well | Puntland Ministry of Energy Minerals and Water | March 29, 2022 | Nugaal | garowe | Rabaable | 0.0 | Community | 29/03/1981 | Rabaable dug well | — | 8.2807114 | 48.2980123 | 559.0 | — | 1 | — | urban | yes | — | Yes | — | 1050 | — | — | — | — | — | — | — | — | — | — | — | — | — | 30.0 | 8.0 | 8.0 | 8.0 | — | 2.0 | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 4.0 | PVC | 500.0 | 1 | 3 | 0 | no | — | — | Submersible Pump | Lowara | 4.0 | 28.0 | Solar | — | — | SZYL-M220-36C | 1.5 | fair | — | yes | Colorless and odorless | 31.2 | 7.8 | 2470.0 | 1231.0 | — | Communal | yes | 29/03/2017 | 2 | 5 | yes | 0.05 | no | — | — | — | ISRC | 29/03/2020 | 1. Construction of steel tank | 1. Rehabilitation of pipelines 2. Extension pipelines 3. Construction of new koisks. 4. Construction of caretaker room. | — | — |
7547 | — | Dug Well | FGS Ministry of Energy and Water Resources | March 16, 2022 | Middle Shabelle | balcad | Garas Bintow | 2.5 | Private | 12/10/2002 | Farjano | — | 2.2172281 | 45.3975772 | 139.0 | — | — | — | rural | yes | — | Yes | — | 1860 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 8.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 50.0 | Galvanised Steel | 50.0 | 320 | 1 | 2 | no | — | — | Submersible Pump | Lowara 5.5kw | — | 113.0 | Generator | Gangfa 115 | — | — | — | poor | In a good condition | no | — | — | — | — | — | — | Private/Individual | — | — | — | — | yes | 0.05 | no | — | — | — | IR | 14-Mar-14 | Construction of animal troughs and communal water point | Full Rehabilitation and supply of pump and GI pipes. | — | — |
7529 | — | Dug Well | Somaliland MoWRD | March 30, 2022 | Awdal | zeylac | caasha caddo | 0.25 | DRC | 30/12/2006 | Aasha caddo | — | 11.1747362 | 43.4406391 | 4.0 | — | 100 | — | urban | yes | — | Yes | — | 3500 | — | — | — | — | — | — | — | — | — | — | — | — | — | 8.0 | 4.0 | 1.5 | 10.0 | 1.5 | 7.0 | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 8.0 | PVC | 950.0 | 500 | 6 | 2 | no | — | — | Submersible Pump | Grundfoz | 1.7 | 7.0 | Solar | — | — | Jt-200 | 1.2 | good | The supply is poor becouse the yeid of the dug well is low | no | — | 31.4 | 8.26 | 1908.0 | 1270.0 | — | Communal | yes | 16/07/2016 | 4 | 3 | yes | 0.05 | no | — | — | — | UNICEF | 23/11/2021 | Bump replacement | Exploration of new boreholes and drilling new boreholes | — | — |
7604 | — | Dug Well | Somaliland MoWRD | May 9, 2022 | Awdal | baki | Baki | 1.0 | Bmz | 08/02/2016 | Baki 2 | — | 10.0279884 | 43.3705481 | 1011.0 | — | 5 | — | urban | yes | — | Yes | — | 10000 | — | — | — | — | — | — | — | — | — | — | — | — | — | 8.0 | 4.0 | 1.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 85.0 | PVC | 3000.0 | 700 | 8 | 0 | no | — | — | Submersible Pump | — | 2.5 | 7.0 | Solar | — | — | Dose | 8.5 | fair | This dugwell is connected to the reservoir | no | — | 33.0 | 7.35 | 834.0 | 595.0 | — | Communal | no | — | — | — | yes | 0.03 | no | — | — | — | — | — | — | — | — | — |
7564 | — | Dug Well | FGS Ministry of Energy and Water Resources | March 16, 2022 | Middle Shabelle | balcad | Diiraley | 4.5 | Private | 13/09/2016 | Diiraley | — | 2.2223083 | 45.3220133 | 163.0 | — | — | — | rural | yes | — | Yes | — | 580 | 0 | 0 | 0 | — | — | — | — | — | — | — | — | — | — | 85.0 | 76.0 | — | 5.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | Plastic tank | 10.0 | PVC | 108.0 | 90 | — | — | no | — | — | Submersible Pump | 5.5kw lowara | — | 81.0 | Generator | Gangfa125 | — | — | — | good | Is a good condition | no | — | — | — | — | — | — | Private/Individual | — | — | — | — | yes | 0.05 | no | — | — | — | Private | 12-Oct-22 | Installation of Solar system and submersible pump | Elevated water tank, Generator and Full rehabilitation | — | — |
7715 | — | Dug Well | FGS Ministry of Energy and Water Resources | May 29, 2022 | Hiraan | beled_weyne | Hilaac | — | — | 23/11/1997 | Nuur Diiriye | — | 4.7336458 | 45.2054732 | — | — | — | — | urban | yes | — | Yes | — | 3600 | — | — | — | — | — | — | — | — | — | — | — | — | — | 16.0 | 12.0 | 3.0 | 1.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 120 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | fair | — | no | — | 33.0 | 7.0 | 1660.0 | 830.0 | — | Private/Individual | — | — | — | — | yes | 0.01 | — | — | — | — | — | — | — | Full Intervention | — | — |
SWALIM is a multi-donor project managed by FAO and currently funded by The European Union, USAID, SDC, FCDO and Government of France