Id | Code | Select the type of water source being inspected | Select the agency inspecting this water source | Enter the date of source inspection | Region | District | Enter the name of settlement / village where the source is located | Distance to nearest settlement (KM) | Select the agency that established this water source | Enter the date when the source was established | Enter the water source name | Source gpspoint | Enter water source Latitude in decimal degrees | Enter water source Longitude in decimal degrees | Enter Elevation (m.a.s.l) | Enter GPS Precision (m) | Enter number of water sources in a cluster | Water Source Photographs | Select the category of users for this water source | Is this a permanent status water source? | For how many months in a year is this water source in use (#)? | Is this water source currently functioning? | Non functioning reason | No. of persons using | No. of Camels using the source | No. of Cattle using the source | No. of Sheep/Goats using the source | Area irrigated using the source (ha) | Is the source protected? | What is the depth of this borehole (m)? | Type of Casing | Casing size (inches) | What is the current static water level of this borehole (m)? | What is the yield of this borehole (m3/hr)? | How long is this borehole operated in a day (hr)? | What is the borehole draw down (m)? | After pumping, how long does this borehole take to recover (hr)? | What is the depth of this dug well (m)? | What is the current static water level of this dug well (m)? | What is the yield of this dug well (m3/hr)? | How long is this dug well operated in a day (hr)? | What is the dug well draw down (m)? | After pumping, how long does this dug well take to recover (hr)? | What is the depth of this dam (m)? | What is the length of this dam (m)? | What is the width of this dam (m)? | What is the depth of this berkad (m)? | What is the length of this berkad (m)? | What is the width of this berkad (m)? | What is the cumulative discharge rate of this spring (m3/hr)? | What is the depth of this source (m)? | What is the length of this source (m)? | What is the width of this source (m)? | What is the yield of the source (m3/hr)? | What type of reservoir is used for this source? | Reservoir capacity (m3) | Pipeline type | Pipeline length (m) | How many House Holds (HH) are connected to this water source? | How many kiosks/water points are connected to this source? | How many animal troughs are connected to this source? | Source used for water trucking during emergency? | No. of trucks / day | Average truck capacity (m3) | Pump type | Pump model | Pump capacity (m3/hr) | Pump level (m) | Power source | Generator/Solar type | Generator capacity (kVA/kWh) | What type/model is the solar used? | What capacity is the solar (kWh)? | Condition of supply system | Additional notes on supply & distribution system condition | Any visible physical problem (color, odor)? | Please describe the color, odor and smell of water | Temperature | PH | Electrical Conductivity (µs/cm) | Total Dissolved Solids (mg/l) | Water sample code. (if taken) | Management type | Water & Sanitation Committee (WSC)? | Year established | WSC members male | WSC members female | DIs water for human use charged? | Current cost of 20 ltr jerrican (USD/20ltr) | Is water for animal use charged? | Current cost for Livestock (USD/100ltr) | What is the name of the operator/caretaker for this water source? | What is the phone number of the operator/caretaker? | Which agency carried out last intervention on this water source? | Recent interventions | Last intervention date | Proposed intervention description | Additional Notes | Metadata Tag |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
8144 | — | Borehole | Somaliland MoWRD | April 11, 2022 | Sool | las_caanood | Dhidinka | 0.0 | ICRC | 11/04/2015 | Dhidinka borehole | — | 8.5171179 | 47.3300951 | 634.0 | — | 2 | — | rural urban | yes | — | Yes | — | 320 | 1000 | 0 | 2500 | 0.0 | — | 385.0 | pvc | 8.0 | 177.0 | 16.0 | 8.0 | 0.0 | 0.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 27.0 | Galvanised Steel | 220.0 | 160 | 1 | 4 | yes | 35 | 45.0 | Submersible Pump | Luwara | 15.0 | 228.0 | Hybrid - Solar/Generator | Perkins | 50.0 | Photovoltiac | 350.0 | good | The supply system is good | no | — | 31.0 | 7.7 | 950.0 | 680.0 | — | Communal | yes | 11/04/2019 | 5 | 2 | no | — | no | — | — | — | Oxfam GB | 14/11/2021 | Solar installed. Pump and cables and fencing also implemented | Lack of pump spare and extra water tank for storage and change the pipe that is needs seen in this borehole | — | — |
7854 | — | Borehole | Somaliland MoWRD | April 16, 2022 | Sool | xudun | Bohol | 1.0 | Imaraat | 11/02/2011 | Bohol bore hole | — | 9.3595923 | 47.29408 | 693.0 | — | 0 | — | urban rural | yes | — | Yes | — | 15000 | 5000 | 0 | 17000 | 0.0 | — | 170.0 | gi | 8.0 | 140.0 | 15.0 | 7.0 | 1.0 | 2.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 170.0 | Stainless Steel | 200.0 | 1 | 1 | 2 | yes | 14 | 12.0 | Submersible Pump | Luwara | 12.0 | 150.0 | Hybrid - Solar/Generator | Parking. | 60.0 | 0 | 0.0 | poor | 1.poor service 2. Poor water supply syatem. | no | — | 42.0 | 6.9 | 3200.0 | 2200.0 | — | Communal | no | — | — | — | no | — | no | — | — | — | Action Afrika Hilfe e.V | 16/12/2020 | 1. Pipe line , pump. Solar installatation. | 1.Water rank rehabilitation. | — | — |
8111 | — | Borehole | Somaliland MoWRD | April 7, 2022 | Sool | las_caanood | Higlo | 1.5 | Private | 07/04/2015 | Geel caseeye | — | 8.5646566 | 47.6841849 | 539.0 | — | 2 | — | rural | yes | — | Yes | — | 0 | 40 | 0 | 0 | 3.0 | — | 65.0 | pvc | 8.0 | 40.0 | 10.0 | 8.0 | 0.0 | 0.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 48.0 | Galvanised Steel | 100.0 | 0 | 0 | 0 | yes | 2 | 8.0 | Submersible Pump | Luwara | 13.0 | 30.0 | Solar | — | — | Szyl-p300- 36 | 300.0 | good | Two solar panels damaged and need to be changed | no | — | 32.0 | 6.8 | 1150.0 | 810.0 | — | Communal | no | — | — | — | no | — | no | — | — | — | Oxfam GB | 07/04/2019 | Constructed water tank of capacity 48 qubic meter | Supply system disconnected due to pipes damage and Water cannot go to water tanks. 2 solar panels also not working | — | — |
8075 | — | Borehole | Somaliland MoWRD | April 18, 2022 | Sanaag | ceerigaabo | Ceerigabo | 1.0 | Somalia government | 18/04/1972 | Cerigabo WD3 | — | 10.6304185 | 47.36284 | 1785.0 | — | 1 | — | urban rural | yes | — | Yes | — | 2000 | 100 | 70 | 500 | 2.0 | — | 82.0 | gi | 8.0 | 70.0 | 20.0 | 12.0 | 15.0 | 0.5 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 25.0 | Stainless Steel | 1000.0 | 1 | 1 | 1 | yes | 15 | 10.0 | Submersible Pump | Luwara | 20.0 | 25.0 | Hybrid - Solar/Generator | Parking | 45.0 | 0 | 0.0 | fair | 1. Poor water supply syatem | no | — | 25.0 | 7.1 | 1300.0 | 120.0 | — | Communal | no | — | — | — | no | — | no | — | — | — | — | 18/04/2022 | 1 | 1 | — | — |
8083 | — | Borehole | Somaliland MoWRD | April 9, 2022 | Sool | las_caanood | Saahdheer | 0.6 | NPA | 09/04/2014 | Saaxdheer borehole | — | 8.0068544 | 47.1039935 | 605.0 | — | 1 | — | rural urban | yes | — | Yes | — | 5000 | 2100 | 0 | 1200 | 0.0 | — | 370.0 | pvc | 8.0 | 324.0 | 12.0 | 6.0 | 0.0 | 0.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 72.0 | Galvanised Steel | 650.0 | 20 | 5 | 7 | yes | 30 | 8.0 | Submersible Pump | Luwara | 45.0 | 320.0 | Hybrid - Solar/Generator | Perkins | 45.0 | BR-M300W | 300.0 | good | All the system are working properly | no | — | 31.0 | 7.4 | 1260.0 | 960.0 | — | Communal | no | — | — | — | no | — | no | — | — | — | CARE Somalia | 09/05/2020 | Construction of generator room. Pipeline extension 2 meters kiosks Construction . Supply of riding pipes and fencing 110 m wires | Rehabilitation of water tank that has leakage and fencing the location of the borehole to protect from an authorised personnel. | — | — |
7855 | — | Borehole | Somaliland MoWRD | April 12, 2022 | Sool | las_caanood | Gumays | 0.2 | NRC | 12/01/2018 | Gumays borehole 1 | — | 8.8429653 | 46.7961158 | 651.0 | — | 2 | — | rural urban | yes | — | Yes | — | 8000 | 500 | 0 | 1350 | 0.0 | — | 150.0 | pvc | 8.0 | 60.0 | 4.0 | 12.0 | 0.0 | 0.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 24.0 | Galvanised Steel | 2000.0 | 300 | 3 | 2 | no | — | — | Submersible Pump | Luwara | 11.0 | 110.0 | Solar | — | — | SZYL-M330.36 | 330.0 | good | The supply system required maintenance because the pipelines are very weak | no | — | 29.0 | 7.3 | 3170.0 | 2200.0 | — | Communal | yes | 12/04/2019 | 3 | 2 | no | — | no | — | — | — | ADRA | 12/04/2020 | Water tank construction | Require generator, pump and pipelines replacement. It also needs to check whole the system | — | — |
7874 | — | Borehole | Somaliland MoWRD | April 24, 2022 | Sanaag | laasqoray | Badhan/Baragaha quled. | 1.0 | Somalia government | 24/04/1986 | Baragaha Qoleed | — | 9.5593722 | 48.4901989 | 869.0 | — | 1 | — | rural urban | yes | — | Yes | — | 13000 | 1100 | 9700 | 25000 | 0.0 | — | 110.0 | gi | 8.0 | 94.0 | 16.0 | 12.0 | 0.0 | 0.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 10.0 | Galvanised Steel | 100.0 | 0 | 2 | 3 | yes | 31 | 10.0 | Submersible Pump | Luwara | 16.0 | 94.0 | Generator | Parkin | 50.0 | — | — | good | Well functioning | no | — | 23.0 | 7.9 | 2800.0 | 1400.0 | — | Communal | no | — | — | — | no | — | no | — | — | — | — | — | 0 | 1. New solar pannels Installation 2. Watchman room building 3. Tw bit laterine _ 1 | — | — |
8043 | — | Borehole | Somaliland MoWRD | April 22, 2022 | Sanaag | laasqoray | Ceel buh | 5.0 | Somaliland MoWRD | — | Ceel buh borehole 2 | — | 10.2212753 | 48.3119846 | 1067.0 | — | 2 | — | rural urban | yes | — | Yes | — | 4800 | 1500 | 500 | 15000 | 0.0 | — | 276.0 | gi | 8.0 | 17.0 | 4.0 | 12.0 | 150.0 | 1.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 12.0 | Galvanised Steel | 100.0 | 1 | 1 | 3 | no | — | — | Submersible Pump | Luwara | 7.5 | 258.0 | Generator | Parkins | 30.0 | — | — | fair | Inadeqauate water supply conditon | no | — | 28.0 | 7.5 | 1450.0 | 394.0 | — | Communal | no | — | — | — | no | — | no | — | — | — | — | — | 0 | 1.new bore hole 2 drilling | — | — |
8024 | — | Dug Well | Somaliland MoWRD | April 12, 2022 | Sool | las_caanood | Gumays | 3.0 | Community | 11/09/1982 | Wadhake | — | 8.8351193 | 46.833536 | 647.0 | — | 1 | — | rural | yes | — | Yes | — | 700 | 1500 | 0 | 8000 | 1.0 | — | — | — | — | — | — | — | — | — | 16.0 | 10.0 | 6.0 | 9.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 6.0 | Galvanised Steel | 140.0 | 0 | 1 | 2 | yes | 10 | 9.0 | Surface mounted Pump | Luwara | 6.0 | — | Solar | — | — | Photovoltiac | 300.0 | good | The system is not working because there is electrical shock pump | no | — | 29.0 | 7.2 | 1560.0 | 1000.0 | — | Communal | yes | 12/04/2019 | 4 | 3 | no | — | no | — | — | — | NRC | 12/11/2019 | Construction of supply system | Solar system is not functioning. Pump is not working due to burning or electrical shock | — | — |
8183 | — | Borehole | Somaliland MoWRD | April 19, 2022 | Sanaag | ceerigaabo | Cerigabo | 2.5 | Kuwait charity | 01/04/2015 | Laaqiciya 1 bore hole | — | 10.6436818 | 47.3037278 | 1875.0 | — | 1 | — | rural urban | yes | — | Yes | — | 1000 | 180 | 400 | 3000 | 1.0 | — | 172.0 | gi | 8.0 | 160.0 | 1.0 | 12.0 | 15.0 | 1.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 24.0 | Stainless Steel | 100.0 | 1 | 3 | 3 | yes | 2 | 10.0 | Submersible Pump | Luwara | 11.0 | 45.0 | Hybrid - Solar/Generator | Parkins | 30.0 | 572350 | 350.0 | good | Properly functining well | no | — | 32.0 | 7.7 | 550.0 | 843.0 | — | Communal | no | — | — | — | no | — | no | — | — | — | — | — | 0 | 1. New pipline installation 1.5 km to school installation. 2. Increase the depth of borehole 7m. | — | — |
SWALIM is a multi-donor project managed by FAO and currently funded by The European Union, USAID, SDC, FCDO and Government of France