Id | Code | Select the type of water source being inspected | Select the agency inspecting this water source | Enter the date of source inspection | Region | District | Enter the name of settlement / village where the source is located | Distance to nearest settlement (KM) | Select the agency that established this water source | Enter the date when the source was established | Enter the water source name | Source gpspoint | Enter water source Latitude in decimal degrees | Enter water source Longitude in decimal degrees | Enter Elevation (m.a.s.l) | Enter GPS Precision (m) | Enter number of water sources in a cluster | Water Source Photographs | Select the category of users for this water source | Is this a permanent status water source? | For how many months in a year is this water source in use (#)? | Is this water source currently functioning? | Non functioning reason | No. of persons using | No. of Camels using the source | No. of Cattle using the source | No. of Sheep/Goats using the source | Area irrigated using the source (ha) | Is the source protected? | What is the depth of this borehole (m)? | Type of Casing | Casing size (inches) | What is the current static water level of this borehole (m)? | What is the yield of this borehole (m3/hr)? | How long is this borehole operated in a day (hr)? | What is the borehole draw down (m)? | After pumping, how long does this borehole take to recover (hr)? | What is the depth of this dug well (m)? | What is the current static water level of this dug well (m)? | What is the yield of this dug well (m3/hr)? | How long is this dug well operated in a day (hr)? | What is the dug well draw down (m)? | After pumping, how long does this dug well take to recover (hr)? | What is the depth of this dam (m)? | What is the length of this dam (m)? | What is the width of this dam (m)? | What is the depth of this berkad (m)? | What is the length of this berkad (m)? | What is the width of this berkad (m)? | What is the cumulative discharge rate of this spring (m3/hr)? | What is the depth of this source (m)? | What is the length of this source (m)? | What is the width of this source (m)? | What is the yield of the source (m3/hr)? | What type of reservoir is used for this source? | Reservoir capacity (m3) | Pipeline type | Pipeline length (m) | How many House Holds (HH) are connected to this water source? | How many kiosks/water points are connected to this source? | How many animal troughs are connected to this source? | Source used for water trucking during emergency? | No. of trucks / day | Average truck capacity (m3) | Pump type | Pump model | Pump capacity (m3/hr) | Pump level (m) | Power source | Generator/Solar type | Generator capacity (kVA/kWh) | What type/model is the solar used? | What capacity is the solar (kWh)? | Condition of supply system | Additional notes on supply & distribution system condition | Any visible physical problem (color, odor)? | Please describe the color, odor and smell of water | Temperature | PH | Electrical Conductivity (µs/cm) | Total Dissolved Solids (mg/l) | Water sample code. (if taken) | Management type | Water & Sanitation Committee (WSC)? | Year established | WSC members male | WSC members female | DIs water for human use charged? | Current cost of 20 ltr jerrican (USD/20ltr) | Is water for animal use charged? | Current cost for Livestock (USD/100ltr) | What is the name of the operator/caretaker for this water source? | What is the phone number of the operator/caretaker? | Which agency carried out last intervention on this water source? | Recent interventions | Last intervention date | Proposed intervention description | Additional Notes | Metadata Tag |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
8337 | — | Borehole | Somaliland MoWRD | April 7, 2022 | Sool | las_caanood | Oodogooye | 7.0 | Private | 03/03/2018 | Ugaaso borehole | — | 8.4864682 | 47.4080974 | 620.0 | — | 2 | — | rural | yes | — | No | The Generator and the pump are not working due electrical shock to the generator and damage to the pump | 4000 | 5000 | 18 | 3000 | 1.0 | — | 330.0 | pvc | 8.0 | 240.0 | 16.0 | 5.0 | 0.0 | 0.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 40.0 | Galvanised Steel | 100.0 | 500 | 1 | 1 | yes | 10 | 8.0 | Submersible Pump | Lawara | 8.0 | 90.0 | Generator | Perkins | 45.0 | — | — | poor | The system is not functioning | no | — | — | — | — | — | — | Private/Individual | — | — | — | — | no | — | no | — | — | — | — | — | No intervention since drilled this borehole | It needs to repair or replace the generator and the pump as well as pipelines | — | — |
7481 | — | Borehole | Somaliland MoWRD | April 11, 2022 | Woqooyi Galbeed | hargeisa | Geed deeble | 0.2 | HWA | 06/06/2013 | K.7.1 borehole | — | 9.78051 | 43.98694 | — | — | 0 | — | urban | yes | — | Yes | — | 31200 | — | — | — | — | — | 207.0 | gi | 8.0 | 47.0 | 63.0 | 23.0 | 0.0 | 0.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 0.0 | Stainless Steel | 30000.0 | 4457 | 0 | 0 | no | — | — | Submersible Pump | Lawara | 60.0 | 58.0 | Electricity Grid | — | — | — | — | fair | Fair supply system | no | — | 24.0 | 7.34 | 900.0 | 450.0 | — | Communal | no | — | — | — | yes | 0.06 | no | — | — | — | — | — | — | No intervention required | — | — |
8587 | — | Borehole | Somaliland MoWRD | April 11, 2022 | Sool | las_caanood | Laascaanood | 5.0 | Private | 01/01/2017 | Nugaal borehole 4 | — | 8.5073342 | 47.4059242 | 619.0 | — | 6 | — | urban | yes | — | No | The is reseve borehole for Nugal water company | — | — | — | — | — | — | 70.0 | pvc | 8.0 | 63.0 | — | — | 0.0 | 0.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 3.0 | Galvanised Steel | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | no | — | — | — | — | — | — | Private/Individual | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
7080 | — | Borehole | Somaliland MoWRD | April 20, 2022 | Woqooyi Galbeed | hargeisa | Wada makaahiil village | 0.3 | UNICEF | 17/08/2015 | Wada makaahiil borehole | — | 9.3606035 | 43.6109003 | 1414.0 | — | 0 | — | rural urban | yes | — | Yes | — | 300 | 1000 | 4000 | 2000 | 0.0 | — | 263.0 | gi | 8.0 | 234.0 | 8.0 | 6.0 | 0.0 | 0.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 12.6 | Galvanised Steel | 200.0 | 2100 | 1 | 3 | no | — | — | Submersible Pump | Grundfos | 3.0 | 243.0 | Generator | Perkins | 30.0 | — | — | poor | The supply system is poor becouse of the borehole yield | no | — | 30.2 | 7.0 | 2700.0 | 1920.0 | — | Communal | no | — | — | — | yes | 0.12 | yes | — | — | — | — | — | — | Borehole replacement, fencing, solar instalation, rehabilitation of animal troughs. | — | — |
7467 | — | Borehole | Somaliland MoWRD | April 23, 2022 | Woqooyi Galbeed | gebiley | Arabsiyo | 1.0 | Hinda sh.yusuf sh.madar | 18/06/2018 | Hinda borehole | — | 9.6571185 | 43.7687795 | 1387.0 | — | 0 | — | urban | yes | — | Yes | — | 12000 | — | — | — | — | — | 146.0 | gi | 8.0 | 79.0 | 6.0 | — | 0.0 | 0.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 50.0 | Galvanised Steel | — | 1714 | 0 | 0 | yes | 18 | 10.0 | Submersible Pump | Grundfos | 20.0 | 110.0 | Hybrid - Solar/Generator | Diesel generating set | 25.0 | Vackson | 12.6 | fair | This borehole condition of supply is fair becouse water tankers from hargeisa come | no | — | 29.0 | 7.5 | 1542.0 | 1090.0 | — | Private/Individual | — | — | — | — | yes | 0.06 | no | — | — | — | — | — | — | — | — | — |
7647 | — | Borehole | Somaliland MoWRD | April 7, 2022 | Togdheer | burco | Burco | 0.4 | Khalifa Foundation UAE | 07/09/2014 | Faras kabood borehole 10 | — | 9.4962028 | 45.5500329 | 1013.0 | — | 0 | — | urban | yes | — | Yes | — | 21000 | — | — | — | — | — | 160.0 | pvc | 8.0 | 93.0 | 28.0 | 17.0 | 0.0 | 0.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 150.0 | PVC | 1800.0 | 21000 | 0 | 0 | no | — | — | Submersible Pump | Grundfoz | 25.0 | 117.0 | Generator | Perkins | 80.0 | — | — | good | Each and every household has connection and access botable water for their water demand | no | — | 0.0 | — | — | — | — | Communal | no | — | — | — | yes | 0.025 | no | — | — | — | — | 05/11/2021 | 6pcs of pipes replaced | No intervention is required | — | — |
7464 | — | Borehole | Somaliland MoWRD | April 24, 2022 | Woqooyi Galbeed | gebiley | Arabsiyo | 0.5 | Amina Aden | 24/04/2021 | Amina Aden borehole | — | 9.6735129 | 43.7705679 | 1357.0 | — | 0 | — | urban | yes | — | Yes | — | 12000 | — | — | — | — | — | 120.0 | gi | 8.0 | 80.0 | 12.0 | 17.0 | 0.0 | 0.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Other | 50.0 | PVC | 100.0 | 1714 | 0 | 0 | yes | 18 | 10.0 | Submersible Pump | Grundfos | 12.0 | 104.0 | Hybrid - Solar/Generator | Perkins | 45.0 | Longi | 12.6 | fair | This water source condition of supply is fair and water tankers from hargeisa take water day and night. | no | — | 28.0 | 7.5 | 1700.0 | 1200.0 | — | Private/Individual | — | — | — | — | yes | 0.06 | no | — | — | — | — | — | — | — | — | — |
7465 | — | Borehole | Somaliland MoWRD | April 23, 2022 | Woqooyi Galbeed | gebiley | Arabsiyo | 0.3 | Sacad Saleban | 22/05/2020 | Sacad Saleeban borehole | — | 9.6724048 | 43.7669518 | 1364.0 | — | 0 | — | urban | yes | — | Yes | — | 12000 | — | — | — | — | — | 80.0 | gi | 8.0 | 30.0 | 12.0 | 18.0 | 0.0 | 0.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Other | 40.0 | PVC | — | 1714 | 0 | 0 | yes | 18 | 10.0 | Submersible Pump | Grundfos | 10.0 | 60.0 | Generator | Perkins | 22.0 | — | — | fair | This borehole condition of supply is fair becouse water tankers from hargeisa come | no | — | 28.0 | 7.3 | 1634.0 | 1160.0 | — | Private/Individual | — | — | — | — | yes | 0.06 | no | — | — | — | — | — | — | — | — | — |
7472 | — | Borehole | Somaliland MoWRD | April 23, 2022 | Woqooyi Galbeed | gebiley | Arabsiyo | 0.8 | Horn of Africa | 18/06/2020 | Arabsiyo borehole 2 | — | 9.6620549 | 43.7683103 | 1381.0 | — | 0 | — | urban | yes | — | Yes | — | 2100 | — | — | — | — | — | 140.0 | gi | 8.0 | 84.0 | 10.0 | 15.0 | 0.0 | 0.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Other | 40.0 | PVC | — | 300 | 2 | 0 | no | — | — | Submersible Pump | Grundfos | 15.0 | 84.0 | Hybrid - Solar/Generator | Perkins | 65.0 | Dusol | 16.38 | good | Fair condition of supply system | no | — | 29.0 | 7.2 | 1186.0 | 806.0 | — | Communal | no | — | — | — | yes | 0.06 | no | — | — | — | — | — | — | Arabsiyo water agent is responsilbe its intervention. | — | — |
7833 | — | Borehole | Somaliland MoWRD | April 1, 2022 | Sool | caynabo | Oog | 1.0 | Chinese government | 01/01/1973 | Oog borehole | — | 8.9271505 | 46.6189696 | 761.0 | — | 1 | — | rural urban | yes | — | Yes | — | 3200 | 400 | 0 | 6000 | 0.0 | — | 75.0 | gi | 6.0 | 20.0 | 6.0 | 7.0 | 0.0 | 0.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 25.0 | Galvanised Steel | 100.0 | 400 | 0 | 2 | no | — | — | Submersible Pump | Laura | 8.0 | 54.0 | Hybrid - Solar/Generator | Perkins | 45.0 | Photovoltiac | 300.0 | good | The all the system are very poor and need complete maintenance from pipes to animal troughs and Water tanks | no | — | 30.0 | 8.0 | 3600.0 | 2300.0 | — | Communal | no | — | — | — | no | — | no | — | — | — | — | — | — | — | — | — |
SWALIM is a multi-donor project managed by FAO and currently funded by The European Union, USAID, SDC, FCDO and Government of France