Id | Code | Select the type of water source being inspected | Select the agency inspecting this water source | Enter the date of source inspection | Region | District | Enter the name of settlement / village where the source is located | Distance to nearest settlement (KM) | Select the agency that established this water source | Enter the date when the source was established | Enter the water source name | Source gpspoint | Enter water source Latitude in decimal degrees | Enter water source Longitude in decimal degrees | Enter Elevation (m.a.s.l) | Enter GPS Precision (m) | Enter number of water sources in a cluster | Water Source Photographs | Select the category of users for this water source | Is this a permanent status water source? | For how many months in a year is this water source in use (#)? | Is this water source currently functioning? | Non functioning reason | No. of persons using | No. of Camels using the source | No. of Cattle using the source | No. of Sheep/Goats using the source | Area irrigated using the source (ha) | Is the source protected? | What is the depth of this borehole (m)? | Type of Casing | Casing size (inches) | What is the current static water level of this borehole (m)? | What is the yield of this borehole (m3/hr)? | How long is this borehole operated in a day (hr)? | What is the borehole draw down (m)? | After pumping, how long does this borehole take to recover (hr)? | What is the depth of this dug well (m)? | What is the current static water level of this dug well (m)? | What is the yield of this dug well (m3/hr)? | How long is this dug well operated in a day (hr)? | What is the dug well draw down (m)? | After pumping, how long does this dug well take to recover (hr)? | What is the depth of this dam (m)? | What is the length of this dam (m)? | What is the width of this dam (m)? | What is the depth of this berkad (m)? | What is the length of this berkad (m)? | What is the width of this berkad (m)? | What is the cumulative discharge rate of this spring (m3/hr)? | What is the depth of this source (m)? | What is the length of this source (m)? | What is the width of this source (m)? | What is the yield of the source (m3/hr)? | What type of reservoir is used for this source? | Reservoir capacity (m3) | Pipeline type | Pipeline length (m) | How many House Holds (HH) are connected to this water source? | How many kiosks/water points are connected to this source? | How many animal troughs are connected to this source? | Source used for water trucking during emergency? | No. of trucks / day | Average truck capacity (m3) | Pump type | Pump model | Pump capacity (m3/hr) | Pump level (m) | Power source | Generator/Solar type | Generator capacity (kVA/kWh) | What type/model is the solar used? | What capacity is the solar (kWh)? | Condition of supply system | Additional notes on supply & distribution system condition | Any visible physical problem (color, odor)? | Please describe the color, odor and smell of water | Temperature | PH | Electrical Conductivity (µs/cm) | Total Dissolved Solids (mg/l) | Water sample code. (if taken) | Management type | Water & Sanitation Committee (WSC)? | Year established | WSC members male | WSC members female | DIs water for human use charged? | Current cost of 20 ltr jerrican (USD/20ltr) | Is water for animal use charged? | Current cost for Livestock (USD/100ltr) | What is the name of the operator/caretaker for this water source? | What is the phone number of the operator/caretaker? | Which agency carried out last intervention on this water source? | Recent interventions | Last intervention date | Proposed intervention description | Additional Notes | Metadata Tag |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
7286 | — | Borehole | FGS Ministry of Energy and Water Resources | April 1, 2022 | Lower Shabelle | wanla_weyn | Baaraan | 1.0 | — | — | Baaraan well | — | 2.6212996 | 44.8900871 | 59.0 | — | 1 | — | urban | no | 8 | Yes | — | 500 | — | — | — | — | — | 150.0 | pvc | 10.0 | 90.0 | 4.0 | 9.0 | 3.0 | 6.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 20.0 | PVC | 1000.0 | 180 | 1 | 3 | yes | 3 | 40.0 | Submersible Pump | Italy | 15.0 | 3.0 | Generator | Doss | 20.0 | — | — | poor | Provide mosque and one displacement Place. | no | — | 0.0 | — | — | — | — | Communal | no | — | — | — | yes | 0.01 | yes | — | — | — | — | — | — | New pump,new generator new solar mantainance tank | — | — |
8443 | — | Borehole | FGS Ministry of Energy and Water Resources | April 18, 2022 | Bay | qansax_dheere | Mookuwow | 5.0 | Agency not specified | — | Hawlaha guud | — | 2.882463 | 43.012622 | — | — | — | — | rural | yes | — | Yes | — | 1600 | — | — | — | — | — | — | gi | — | — | 15.0 | 8.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Plastic tank | — | Stainless Steel | — | 500 | — | — | yes | 20 | 3.0 | Surface mounted Pump | — | — | — | Generator | — | — | — | — | good | — | no | — | — | — | — | — | — | Communal | yes | — | 5 | 0 | — | — | — | — | — | — | — | — | — | Rehabikitation | — | — |
7322 | — | Borehole | Somaliland MoWRD | April 7, 2022 | Togdheer | burco | Burco | 0.1 | JAALIYADA | — | Jaaliyada borehole 5 | — | 9.5484122 | 45.5423075 | 1022.0 | — | 0 | — | urban | yes | — | Yes | — | 21000 | — | — | — | — | — | 200.0 | gi | 10.0 | 106.0 | 14.0 | 17.0 | 0.0 | 0.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Other | 0.0 | PVC | 500.0 | 3000 | 0 | 0 | no | — | — | Submersible Pump | Grundfoz | 15.0 | 123.0 | Generator | Perkins | 45.0 | — | — | good | Each and every household has connection and access botable water for their water demand | no | — | 26.6 | 6.88 | 2620.0 | 1580.0 | — | Communal | no | — | — | — | yes | 0.025 | yes | — | — | — | — | 06/05/2021 | Riser pipe replacement | No intervention required | — | — |
7307 | — | Borehole | Galmudug Ministry of Energy and Water Resources | April 11, 2022 | Mudug | galkayo | laasacadale | 1.4 | — | — | laasacadale Borehole | — | 6.60527 | 47.4200867 | 299.0 | — | 0 | — | rural | yes | — | Yes | — | 2400 | 10780 | — | 85900 | — | — | 180.0 | pvc | 8.0 | — | 10.0 | 14.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 50.0 | Galvanised Steel | 98.0 | 0 | 1 | 3 | yes | 15 | 10.0 | Submersible Pump | grunfos | — | 86.0 | Hybrid - Solar/Generator | Doutz | 32.0 | 340w | 20.0 | poor | not have water disribtion pipes | no | — | 30.8 | 7.72 | 785.0 | 546.0 | — | Communal | — | — | — | — | yes | 0.001 | yes | — | — | — | IOM | solar | — | 2021-07-11 | — | — |
7410 | — | Borehole | Somaliland MoWRD | May 9, 2022 | Togdheer | burco | Sheekh Bashiir | 1.0 | Privately owned Borehole | — | Barqo dhereg Borehole | — | 9.51400333084166 | 45.5528695788235 | 1019.0 | — | 2 | — | rural urban | yes | — | Yes | — | 100 | 0 | 0 | 0 | 0.0 | — | 127.0 | pvc | 8.0 | 110.0 | 24.0 | 20.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Other | 40.0 | Galvanised Steel | 1000.0 | 1500 | 0 | 0 | yes | 10 | 8.0 | Submersible Pump | Laware | 15.0 | 117.0 | Generator | Perkins | 45.0 | — | — | good | Good Condition | no | — | 29.0 | 7.6 | 1500.0 | 500.0 | — | Private/Individual | — | — | — | — | yes | 0.2 | no | — | — | — | — | — | — | Solar installation | — | — |
7338 | — | Borehole | Somaliland MoWRD | May 21, 2022 | Awdal | borama | Dilla | 1.0 | Not specified | — | Dilla Bh 1 | — | 9.7684344 | 43.3359256 | 1583.0 | — | — | — | urban rural | yes | — | Yes | — | 3500 | 400 | 1000 | 3000 | — | — | 84.0 | gi | 8.0 | 50.0 | 8.0 | 3.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 33.0 | Galvanised Steel | 150.0 | 500 | 1 | 2 | no | — | — | Submersible Pump | Lowara | 11.0 | 75.0 | Generator | Perkin | 37.0 | — | — | fair | — | yes | — | 30.0 | 7.2 | 2065.0 | 1870.0 | — | Communal | no | — | — | — | yes | 0.05 | yes | — | — | — | — | — | — | — | — | — |
7346 | — | Borehole | Puntland Ministry of Energy Minerals and Water | April 19, 2022 | Sanaag | ceerigaabo | Balibusle | 5.0 | — | — | Balibusle borehole | — | 10.0501626 | 48.586565 | 1023.0 | — | 1 | — | urban rural | yes | — | Yes | — | 10800 | 1500 | — | 6000 | — | — | 350.0 | pvc | 8.0 | 300.0 | 8.0 | 12.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 16.0 | Galvanised Steel | — | — | — | 2 | yes | 7 | 9.0 | Submersible Pump | — | — | — | Generator | LTG185G1 | 30.0 | — | — | fair | The village has no water supply system. No water kiosks in the village | no | — | 32.1 | 7.1 | 3930.0 | 1977.0 | — | Communal | no | — | — | — | yes | 0.04 | yes | — | — | — | GUMCO | 13/02/2021 | Replacement of distribution pipe line | 1: Amergrncy replacement of main raising pipes and submersible pump 2: Generator 3: Solar 4: Construction of another elevated water tank. 5: Construction of 2 animal water troughs. 6: Replacement of rusted distribution pipes. 7: Construction of caretaker room. 8: Construction of another borehole due to water demand | — | — |
7357 | — | Borehole | FGS Ministry of Energy and Water Resources | April 18, 2022 | Bay | qansax_dheere | Ceel cade | 4.0 | Agency not specified | — | Ceel cade | — | 3.02001 | 42.8863 | — | — | — | — | rural | yes | — | Yes | — | — | — | — | — | 1.0 | — | 3.0 | pvc | 0.0 | — | 3.0 | 8.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 5.0 | PVC | — | — | — | — | yes | — | — | Submersible Pump | — | 4.0 | 2.0 | Electricity Grid | — | — | — | — | poor | — | no | — | — | — | — | — | — | Communal | yes | — | 5 | 0 | yes | — | no | — | — | — | — | — | — | Rehabilitation | — | — |
7365 | — | Borehole | FGS Ministry of Energy and Water Resources | April 18, 2022 | Bay | qansax_dheere | Sheed kus | 6.0 | Agency not specified | — | Sheed kus | — | 2.761155 | 42.88688 | — | — | — | — | rural | yes | — | Yes | — | — | — | — | — | 0.25 | — | 4.0 | gi | — | — | 3.0 | 12.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | — | PVC | 2.0 | — | — | — | yes | 12 | 3.0 | Surface mounted Pump | — | — | — | Generator | — | — | — | — | good | — | no | — | — | — | — | — | — | Communal | yes | — | 5 | 0 | yes | 3 | yes | — | — | — | — | — | — | Rehabilitation | — | — |
7384 | — | Borehole | FGS Ministry of Energy and Water Resources | March 31, 2022 | Lower Juba | kismayo | Caafi- Farjano | 5.0 | Private | — | Caafi Ibrahim | — | -0.3393193 | 42.536169 | 13.0 | — | 11 | — | rural urban | yes | — | Yes | — | 55000 | 0 | 0 | 0 | 0.0 | — | 80.0 | pvc | — | 25.0 | 30.0 | 12.0 | 78.0 | 15.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 180.0 | PVC | 25.0 | 9100 | 9 | 0 | yes | 5 | 20.0 | Submersible Pump | — | 50.0 | 18.0 | Solar | — | — | — | 300.0 | good | Watwr yield is very low and cannot reach all the communities as required | no | — | — | — | — | — | — | Private/Individual | — | — | — | — | yes | 1 | no | — | — | — | — | 28-Dec-21 | Pumping system, more sloar | Need pumping support, more solar bundles and machine for filteration | — | — |
SWALIM is a multi-donor project managed by FAO and currently funded by The European Union, AICS, SDC, FCDO and Government of France