Id | Code | Select the type of water source being inspected | Select the agency inspecting this water source | Enter the date of source inspection | Region | District | Enter the name of settlement / village where the source is located | Distance to nearest settlement (KM) | Select the agency that established this water source | Enter the date when the source was established | Enter the water source name | Source gpspoint | Enter water source Latitude in decimal degrees | Enter water source Longitude in decimal degrees | Enter Elevation (m.a.s.l) | Enter GPS Precision (m) | Enter number of water sources in a cluster | Water Source Photographs | Select the category of users for this water source | Is this a permanent status water source? | For how many months in a year is this water source in use (#)? | Is this water source currently functioning? | Non functioning reason | No. of persons using | No. of Camels using the source | No. of Cattle using the source | No. of Sheep/Goats using the source | Area irrigated using the source (ha) | Is the source protected? | What is the depth of this borehole (m)? | Type of Casing | Casing size (inches) | What is the current static water level of this borehole (m)? | What is the yield of this borehole (m3/hr)? | How long is this borehole operated in a day (hr)? | What is the borehole draw down (m)? | After pumping, how long does this borehole take to recover (hr)? | What is the depth of this dug well (m)? | What is the current static water level of this dug well (m)? | What is the yield of this dug well (m3/hr)? | How long is this dug well operated in a day (hr)? | What is the dug well draw down (m)? | After pumping, how long does this dug well take to recover (hr)? | What is the depth of this dam (m)? | What is the length of this dam (m)? | What is the width of this dam (m)? | What is the depth of this berkad (m)? | What is the length of this berkad (m)? | What is the width of this berkad (m)? | What is the cumulative discharge rate of this spring (m3/hr)? | What is the depth of this source (m)? | What is the length of this source (m)? | What is the width of this source (m)? | What is the yield of the source (m3/hr)? | What type of reservoir is used for this source? | Reservoir capacity (m3) | Pipeline type | Pipeline length (m) | How many House Holds (HH) are connected to this water source? | How many kiosks/water points are connected to this source? | How many animal troughs are connected to this source? | Source used for water trucking during emergency? | No. of trucks / day | Average truck capacity (m3) | Pump type | Pump model | Pump capacity (m3/hr) | Pump level (m) | Power source | Generator/Solar type | Generator capacity (kVA/kWh) | What type/model is the solar used? | What capacity is the solar (kWh)? | Condition of supply system | Additional notes on supply & distribution system condition | Any visible physical problem (color, odor)? | Please describe the color, odor and smell of water | Temperature | PH | Electrical Conductivity (µs/cm) | Total Dissolved Solids (mg/l) | Water sample code. (if taken) | Management type | Water & Sanitation Committee (WSC)? | Year established | WSC members male | WSC members female | DIs water for human use charged? | Current cost of 20 ltr jerrican (USD/20ltr) | Is water for animal use charged? | Current cost for Livestock (USD/100ltr) | What is the name of the operator/caretaker for this water source? | What is the phone number of the operator/caretaker? | Which agency carried out last intervention on this water source? | Recent interventions | Last intervention date | Proposed intervention description | Additional Notes | Metadata Tag |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
7685 | — | Dug Well | Somaliland MoWRD | May 9, 2022 | Awdal | zeylac | Garbodadar | 1.5 | UNICEF | 08/03/2017 | Garbodadar dug well | — | 10.2208626 | 43.6261773 | 468.0 | — | — | — | urban | yes | — | Yes | — | 17500 | — | — | — | — | — | — | — | — | — | — | — | — | — | 9.0 | 3.0 | 3.0 | 8.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 24.0 | PVC | 3000.0 | 2500 | 6 | 0 | no | — | — | Submersible Pump | — | 3.5 | 8.0 | Solar | — | — | Axitec | 5.6 | fair | The supply is well connected to a public points within the village | no | — | — | — | — | — | — | Utility/Local Authority | — | — | — | — | yes | 0.02 | no | — | — | — | GIZ | — | Construction of reservoir | Reservoir geomembrane replacement | — | — |
7692 | — | Dug Well | Somaliland MoWRD | May 7, 2022 | Awdal | zeylac | Xariirad | 1.0 | Community | 01/04/1986 | Xariirad dug wells | — | 10.32369 | 42.83967 | — | — | 2 | — | urban | yes | — | Yes | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 9.0 | 2.0 | 16.0 | 12.0 | 0.5 | 0.3 | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 50.0 | PVC | 3000.0 | 600 | 0 | 0 | no | — | — | Submersible Pump | — | 15.0 | 8.0 | Hybrid - Solar/Generator | Perkin | 15.0 | — | — | fair | There is more than 600 household with connected water. But the public places are not connected well. | no | — | 29.0 | 7.2 | 776.0 | 550.0 | — | Private/Individual | — | — | — | — | yes | 0.011 | no | — | — | — | — | — | — | Generator, | — | — |
7693 | — | Dug Well | FGS Ministry of Energy and Water Resources | May 30, 2022 | Hiraan | beled_weyne | Bulada | — | — | 19/12/1998 | Waadi | — | 4.449 | 45.1217 | — | — | — | — | urban | yes | — | Yes | — | 9000 | — | — | — | — | — | — | — | — | — | — | — | — | — | 11.0 | 10.0 | 7.0 | 20.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | Plastic tank | 4.0 | — | — | 300 | — | — | no | — | — | — | — | — | — | — | — | — | — | — | fair | — | no | — | 33.0 | 7.0 | 6620.0 | 3080.0 | — | Private/Individual | — | — | — | — | yes | 0.01 | — | — | — | — | — | — | — | Rehabilitation of the water tank, deepening of the source and supply of new generator | — | — |
7694 | — | Dug Well | FGS Ministry of Energy and Water Resources | May 29, 2022 | Hiraan | beled_weyne | Buundaweyn | — | Private | 23/08/2002 | Khaliifa | — | 4.445 | 45.1223 | — | — | — | — | urban | yes | — | Yes | — | 1800 | — | — | — | — | — | — | — | — | — | — | — | — | — | 90.0 | 10.0 | 5.0 | 20.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 16.0 | Galvanised Steel | — | 300 | — | — | — | — | — | Submersible Pump | — | — | — | Generator | — | — | — | — | fair | — | no | — | 33.0 | 7.0 | 5170.0 | 2590.0 | — | Private/Individual | — | — | — | — | yes | 0.01 | — | — | — | — | — | — | — | Full Rehabilitation | — | — |
7695 | — | Dug Well | FGS Ministry of Energy and Water Resources | May 30, 2022 | Hiraan | beled_weyne | Xaafada Afaraad | — | — | 25/11/2015 | Towfiq 1 | — | 4.4458 | 45.113 | — | — | — | — | urban | yes | — | Yes | — | 15000 | — | — | — | — | — | — | — | — | — | — | — | — | — | 13.0 | 12.0 | 5.0 | 21.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 9.0 | — | — | 2500 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | poor | — | no | — | 33.0 | 7.0 | 5000.0 | 2500.0 | — | Private/Individual | — | — | — | — | yes | 0.01 | — | — | — | — | — | — | — | Rehabilitation of the water tank and supply of new generator | — | — |
7696 | — | Dug Well | FGS Ministry of Energy and Water Resources | May 30, 2022 | Hiraan | beled_weyne | Dhagaxjibis | — | — | 22/08/2006 | Sam Sam | — | 4.4411 | 45.1244 | — | — | — | — | urban | yes | — | Yes | — | 18000 | — | — | — | — | — | — | — | — | — | — | — | — | — | 13.0 | 10.0 | 15.0 | 20.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 14.0 | — | — | 3000 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | fair | — | no | — | 32.0 | 10.0 | 4600.0 | 2330.0 | — | Private/Individual | — | — | — | — | yes | 0.01 | — | — | — | — | — | — | — | Rehabilitation of water tank and supply of new generator | — | — |
8772 | — | Borehole | APD | April 11, 2022 | Bay | diinsoor | Gyy | — | ADRA | 11/04/2022 | Nugaal | — | 8.5068311 | 47.4043835 | 624.0 | — | 4 | — | urban | no | — | No | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | no | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
7697 | — | Dug Well | FGS Ministry of Energy and Water Resources | May 30, 2022 | Hiraan | beled_weyne | Buundaweyn | — | — | 22/07/1996 | Caduun | — | 4.449 | 45.1217 | — | — | — | — | rural | yes | — | Yes | — | 600 | — | — | — | — | — | — | — | — | — | — | — | — | — | 12.0 | 10.0 | 7.0 | 12.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | Plastic tank | 4.0 | — | — | 100 | — | — | no | — | — | — | — | — | — | — | — | — | — | — | fair | — | no | — | 33.0 | 7.0 | 4300.0 | 2170.0 | — | Private/Individual | — | — | — | — | yes | 0.01 | — | — | — | — | — | — | — | Full Rehabilitation and supply of new generator | — | — |
7698 | — | Dug Well | FGS Ministry of Energy and Water Resources | May 29, 2022 | Hiraan | beled_weyne | Jawiil | — | — | 18/05/2001 | Waadi | — | 4.91747 | 45.22123 | — | — | 2 | — | rural | yes | — | Yes | — | 3600 | 800 | 100 | 600 | — | — | — | — | — | — | — | — | — | — | 15.0 | 12.0 | 2.0 | 12.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 20.0 | — | — | 300 | — | — | — | — | — | Submersible Pump | Electric Pump | — | — | — | — | — | — | — | fair | — | no | — | 29.0 | 7.7 | 3560.0 | 1810.0 | — | Communal | — | — | — | — | yes | 0.01 | — | — | — | — | WARDI | 23-Jun-15 | Solar Powered System | Full Rehabilitation | — | — |
7708 | — | Dug Well | Puntland Ministry of Energy Minerals and Water | April 9, 2022 | Sanaag | laasqoray | Midigale | 0.5 | ADESO | 01/01/2003 | Midigale dugwell 1 | — | 10.6839932 | 48.6763163 | 809.0 | — | 3 | — | urban | yes | — | Yes | — | 900 | — | — | — | — | — | — | — | — | — | — | — | — | — | 12.0 | 5.0 | 3.5 | 2.0 | 7.0 | 24.0 | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 25.0 | PVC | 1500.0 | 60 | 1 | — | no | — | — | Submersible Pump | Luwara | — | 12.0 | Solar | — | — | — | 3.0 | poor | 1:Submersible pump is not functioning properly. 2:And the well needs to be expanded deeply. | no | — | 32.1 | 7.5 | 1987.0 | 995.0 | — | Communal | — | — | — | — | yes | 0.01 | no | — | — | — | CARE-Somaliland | 01/01/2017 | Elevated water tank Solar Submersible pump | 1:Immediate change of the submersible pump 2:PVC pipes 3:Digging the well deeply 4:Generator if possible or solar power storage of battery. | — | — |