Code BHGDGA006
Water Source Type Borehole
Inspecting Agency FGS_MoEWR
Inspection Date Oct. 10, 2019
District Garbahaarey
Settlement Name Shabeel
Settlement Distance None
Establishing Agency Former Somali Government
Establishing Date 11-11-85
Source Name Garbaharey 1
Geometry None
Latitude 3.33411
Longitude 42.21629
Sources Cluster None
Water Source Photo
Users Urban
Permanent? Yes
Months Used None
Functioning? Yes
Non Function Reason None
No of Humans None
No of Camels None
No of Cattle None
No of Shoats None
Irrigation Area None
Source Protected? None
Borehole Depth 102.0
Wellcasing Type GI
Wellcasing Size 2.0
Borehole SWL 7.0
Borehole Operating Yield 24.0
Borehole Operating Hours 11.0
Borehole Operating Drawn 44.0
Borehole Recovery Time 4.0
Reservoir Type Concrete/Masonry tank
Reservoir Capacity 100.0
Pipeline Type PVC
Pipeline Length 3000.0
HouseHold Connections 2000
Water Point Kiosks 2
Troughs 1
Source Emergency? Yes
No of Trucks 6
Truck Capacity 8.0
Pump Type Submersible Pump
Pump Model Grundfos
Pump Capacity 11.0
Pump Level 48.0
Power Source Generator
Generator Type Fiat
Generator Capacity 145.0
Solar Type None
Solar Capacity None
Supply Condition Good
Supply System Condition Notes None
Physical Water Issues No
Physical Problem Reason None
Temperature 33.5
pH 6.84
Electrical Conductivity 5580.0
Total Dissolved Solids 2720.0
Water Sample Code No Document
Management Type Private-Public-Partnership
WSC None
WSC Established Date None
WSC Male None
WSC Female None
Humans Charged for Water? Yes
Cost Of Water for Humans 0.1
Water Charged for Animals? No
Cost Of Water for Animals None
Last Intervention Agency None
Last Intervention Description New submersible pump installed, pressure pump changed, 1200m new pipline installed, ( in february 2019 the Napad organisation was built two concrete elevated tank 50m3, 30m3) (iom installed solar system of 126 panel 31kw, generator restor, fence, 2 k
Last Intervention Date June 9, 2019
Proposed Intervention Description Solar system 80kw, standby generator, pressure pump for water distribution, filter RO, 2 elevated tanks 50m3, pipline 6000m PVC class D, 2 kiosk. Furthermore, the water from this borehole used to filter before distribution by using RO filter system.
Additional Notes None
Metadata Tag Strategic Water Sources Survey – WSS_NAT
History watersource.HistoricalWaterSource.None