Id | Code | Select the type of water source being inspected | Select the agency inspecting this water source | Enter the date of source inspection | Region | District | Enter the name of settlement / village where the source is located | Distance to nearest settlement (KM) | Select the agency that established this water source | Enter the date when the source was established | Enter the water source name | Source gpspoint | Enter water source Latitude in decimal degrees | Enter water source Longitude in decimal degrees | Enter Elevation (m.a.s.l) | Enter GPS Precision (m) | Enter number of water sources in a cluster | Water Source Photographs | Select the category of users for this water source | Is this a permanent status water source? | For how many months in a year is this water source in use (#)? | Is this water source currently functioning? | Non functioning reason | No. of persons using | No. of Camels using the source | No. of Cattle using the source | No. of Sheep/Goats using the source | Area irrigated using the source (ha) | Is the source protected? | What is the depth of this borehole (m)? | Type of Casing | Casing size (inches) | What is the current static water level of this borehole (m)? | What is the yield of this borehole (m3/hr)? | How long is this borehole operated in a day (hr)? | What is the borehole draw down (m)? | After pumping, how long does this borehole take to recover (hr)? | What is the depth of this dug well (m)? | What is the current static water level of this dug well (m)? | What is the yield of this dug well (m3/hr)? | How long is this dug well operated in a day (hr)? | What is the dug well draw down (m)? | After pumping, how long does this dug well take to recover (hr)? | What is the depth of this dam (m)? | What is the length of this dam (m)? | What is the width of this dam (m)? | What is the depth of this berkad (m)? | What is the length of this berkad (m)? | What is the width of this berkad (m)? | What is the cumulative discharge rate of this spring (m3/hr)? | What is the depth of this source (m)? | What is the length of this source (m)? | What is the width of this source (m)? | What is the yield of the source (m3/hr)? | What type of reservoir is used for this source? | Reservoir capacity (m3) | Pipeline type | Pipeline length (m) | How many House Holds (HH) are connected to this water source? | How many kiosks/water points are connected to this source? | How many animal troughs are connected to this source? | Source used for water trucking during emergency? | No. of trucks / day | Average truck capacity (m3) | Pump type | Pump model | Pump capacity (m3/hr) | Pump level (m) | Power source | Generator/Solar type | Generator capacity (kVA/kWh) | What type/model is the solar used? | What capacity is the solar (kWh)? | Condition of supply system | Additional notes on supply & distribution system condition | Any visible physical problem (color, odor)? | Please describe the color, odor and smell of water | Temperature | PH | Electrical Conductivity (µs/cm) | Total Dissolved Solids (mg/l) | Water sample code. (if taken) | Management type | Water & Sanitation Committee (WSC)? | Year established | WSC members male | WSC members female | DIs water for human use charged? | Current cost of 20 ltr jerrican (USD/20ltr) | Is water for animal use charged? | Current cost for Livestock (USD/100ltr) | What is the name of the operator/caretaker for this water source? | What is the phone number of the operator/caretaker? | Which agency carried out last intervention on this water source? | Recent interventions | Last intervention date | Proposed intervention description | Additional Notes | Metadata Tag |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1850 | BHTGBC084 | Borehole | Somaliland_MoWRD | Oct. 12, 2019 | Togdheer | Burco | Burco | 0.0 | Community | 12-10-07 | Indha dero borehole | — | 9.5358 | 45.5425 | 1041.0 | 4.9 | — | 1570867510198.jpg | Urban | Yes | — | Yes | — | — | — | — | — | — | — | 195.0 | PVC | 8.0 | 153.0 | 16.0 | 24.0 | — | 0.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 25.0 | PVC | 6.0 | 1500 | 0 | 0 | No | — | — | Submersible Pump | Grundfos | 16.0 | 190.0 | Generator | Perkins | 45.0 | — | — | — | — | No | — | 29.6 | 8.01 | 3076.0 | 1880.0 | — | Private/Individual | — | — | — | — | No | — | No | — | — | — | — | — | — | Pipe and the pump, sanitation staff training | — | Strategic Water Sources Survey – WSS_NATl |
1853 | BHTGBC087 | Borehole | Somaliland_MoWRD | Oct. 10, 2019 | Togdheer | Burco | Burco | 0.0 | Community | 10-10-12 | Jambaq borehole | — | 9.5323 | 45.547 | 1039.0 | 4.9 | 3 | 1570709364891.jpg | Urban | Yes | — | Yes | — | — | — | — | — | — | — | 165.0 | PVC | 8.0 | 97.0 | 35.0 | 6.0 | — | 0.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 60.0 | PVC | 6.0 | 0 | 0 | 0 | Yes | 25 | 40.0 | Submersible Pump | Lowara Italy | 18.0 | 128.0 | Generator | Perkins | 36.0 | — | — | Poor | — | No | — | 29.0 | 9.05 | 2970.0 | 1510.0 | — | Private/Individual | — | — | — | — | No | — | No | — | — | — | Farjanno | Pump and dynamo | 2019-02-24 | Pumb and solar system | — | Strategic Water Sources Survey – WSS_NATl |
1859 | BHTGBC093 | Borehole | Somaliland_MoWRD | Oct. 10, 2019 | Togdheer | Burco | Burco | 0.0 | Community | 04-04-17 | Siilaanyo Borehole | — | 9.5186 | 45.5518 | 1035.0 | 4.9 | 3 | 1570710567198.jpg | Urban | Yes | — | Yes | — | — | — | — | — | — | — | 108.0 | GI | 8.0 | 50.0 | 10.0 | 18.0 | — | 0.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 25.0 | PVC | 6.0 | 5000 | 0 | 0 | No | — | — | Submersible Pump | Lowara Italy | 10.0 | 100.0 | Generator | Perkins | 45.0 | — | — | Poor | — | No | — | 30.1 | 7.55 | 2000.0 | 10.0 | — | Private/Individual | — | — | — | — | No | — | No | — | — | — | — | — | — | Pump and raiser pipe | — | Strategic Water Sources Survey – WSS_NATl |
1857 | BHTGBC091 | Borehole | Somaliland_MoWRD | Sept. 26, 2019 | Togdheer | Burco | burco | 0.0 | Emirates | 22-03-12 | Borehole10 | — | 9.4962 | 45.5501 | 1032.0 | 4.9 | 1 | 1569486728360.jpg | Urban | Yes | — | Yes | — | — | — | — | — | — | — | 160.0 | PVC | 8.0 | 93.0 | 34.0 | 18.0 | 8.0 | 0.007 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 100.0 | PVC | 6.0 | 1800 | 0 | 0 | No | — | — | Submersible Pump | Grundfos European | 34.0 | 117.0 | Generator | Perkins | 80.0 | — | — | Good | — | No | — | 32.9 | 6.74 | 294.0 | 1470.0 | — | Utility/Local Authority | — | — | — | — | Yes | 0.002 | No | — | — | — | DRC - Danish Refugee Council (Regional Office) | Pump pipe | 2019-03-21 | Generator, fence, pump, water meter, generator room solar system | — | Strategic Water Sources Survey – WSS_NATl |
36 | BHAWBO029 | Borehole | Somaliland_MoWRD | Dec. 2, 2019 | Awdal | Borama | Shaylaha | 0.0 | Kuwait Government | 04-06-13 | Shaylaha BH15 | — | 9.909 | 43.2027 | 1487.0 | 4.3 | 1 | 1575278500942.jpg | — | Yes | — | Abandoned | Since july 2017,at this borehole water dry | — | 0 | 0 | 0 | — | — | 120.0 | GI | 8.0 | 119.0 | 0.0 | 0.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 100.0 | Galvanised Steel | 300.0 | 0 | 0 | 0 | No | — | — | Submersible Pump | Lowara | 7.5 | 102.0 | — | — | — | — | — | Poor | There no system | No | — | — | — | — | — | — | Communal | — | — | — | — | No | — | No | — | — | — | — | — | — | Digging another borehole | — | Strategic Water Sources Survey – WSS_NATl |
37 | BHAWBO030 | Borehole | Somaliland_MoWRD | Dec. 3, 2019 | Awdal | Borama | Qorgaab | 1.0 | — | — | Qoorgaab | — | 9.9415 | 43.2064 | 1425.0 | 4.3 | — | 1575353012979.jpg | — | Yes | — | Yes | — | — | 0 | 0 | 0 | 0.0 | — | 200.0 | GI | 8.0 | 60.0 | 3.0 | 17.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 50.0 | Galvanised Steel | 50.0 | 1 | 0 | 0 | No | — | — | Submersible Pump | Grundfos | 18.0 | — | Electricity Grid | — | — | — | — | Good | — | No | — | 17.0 | 7.9 | 2460.0 | 1760.0 | — | Private/Individual | — | — | — | — | No | — | No | — | — | — | Somaliland MoWR - Ministry of Water Resources | — | — | Installation of solar system | — | Strategic Water Sources Survey – WSS_NATl |
45 | BHAWBO036 | Borehole | Somaliland_MoWRD | Dec. 1, 2019 | Awdal | Borama | Daremacaane | 0.5 | Oxfam GB | 16-05-85 | Shifo BH1 | — | 9.9706 | 43.2182 | 1362.0 | 4.3 | — | 1575198948902.jpg | Rural | Yes | — | Yes | — | — | 0 | 0 | 150 | 100.0 | — | 52.0 | GI | 8.0 | 10.0 | 3.0 | 10.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 30.0 | Galvanised Steel | 10.0 | 0 | 0 | 0 | No | — | — | Submersible Pump | Lowara | 11.0 | 42.0 | Generator | Perkins | 45.0 | — | — | Good | — | No | — | 20.0 | 7.7 | 2080.0 | 1470.0 | — | Private/Individual | — | — | — | — | No | — | No | — | — | — | — | — | — | Construction of new animal troughs and water points. Construction elevated water tank | — | Strategic Water Sources Survey – WSS_NATl |
51 | BHAWBO042 | Borehole | Somaliland_MoWRD | Dec. 1, 2019 | Awdal | Borama | Daremacane | 0.5 | Private | 19-04-96 | Shifo BH2 | — | 9.9695 | 43.2197 | 1362.0 | 4.3 | 1 | 1575203271177.jpg | Urban | Yes | — | Yes | — | — | — | — | — | — | — | 50.0 | GI | 8.0 | 8.0 | 10.0 | 6.0 | — | 0.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 60.0 | Galvanised Steel | 60.0 | 0 | 0 | 0 | No | — | — | Submersible Pump | Grundfos | 11.0 | 28.0 | Generator | Perkins | 250.0 | — | — | Good | — | No | — | — | — | — | — | — | Private/Individual | — | — | — | — | No | — | No | — | — | — | — | — | — | This borehole required Increasing the depth Solar system | — | Strategic Water Sources Survey – WSS_NATl |
7378 | — | Borehole | FGS Ministry of Energy and Water Resources | April 19, 2022 | Bakool | tayeeglow | Tieglow | 2.0 | Community | — | Biyooley 2 | — | 3.9375 | 44.3409 | — | — | — | — | rural | no | 5 | Abandoned | — | — | — | 1 | 0 | 1.0 | — | 120.0 | gi | 0.0 | 80.0 | 6.0 | 8.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | — | Other | 10.0 | — | — | — | yes | — | — | Submersible Pump | — | — | — | Solar | — | — | — | — | poor | — | no | — | — | — | — | — | — | Communal | yes | — | 6 | — | yes | 2 | no | — | — | — | — | — | — | Rehabilitation(Deeping and fencing is needed) | — | — |
1924 | BHTGBC156 | Borehole | Somaliland_MoWRD | Sept. 27, 2019 | Togdheer | Burco | Qoryaale | 2.0 | IR - Islamic Relief | 03-02-17 | Qoryale borehole | — | 9.0828 | 45.9736 | 896.0 | 4.9 | 0 | 1569576544317.jpg | Rural Urban | Yes | — | Yes | — | — | 5000 | 100 | 20000 | 0.5 | — | 350.0 | PVC | 8.0 | 240.0 | 8.0 | 8.0 | 10.0 | 0.33 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 25.0 | PVC | 6.0 | 1400 | 3 | 6 | No | — | — | Submersible Pump | European | 8.0 | 240.0 | Hybrid - Solar/Generator | Perkins | 37.0 | 32 pannels | 36.0 | Good | — | No | — | 30.1 | 7.87 | 334.0 | 1670.0 | — | Utility/Local Authority | — | — | — | — | No | — | No | — | — | — | — | — | — | Fence, operator room and pump | — | Strategic Water Sources Survey – WSS_NATl |
SWALIM is a multi-donor project managed by FAO and currently funded by The European Union, USAID, SDC, FCDO and Government of France