Database :: SWIMS
Id Code Select the type of water source being inspected Select the agency inspecting this water source Enter the date of source inspection Region District Enter the name of settlement / village where the source is located Distance to nearest settlement (KM) Select the agency that established this water source Enter the date when the source was established Enter the water source name Source gpspoint Enter water source Latitude in decimal degrees Enter water source Longitude in decimal degrees Enter Elevation (m.a.s.l) Enter GPS Precision (m) Enter number of water sources in a cluster Water Source Photographs Select the category of users for this water source Is this a permanent status water source? For how many months in a year is this water source in use (#)? Is this water source currently functioning? Non functioning reason No. of persons using No. of Camels using the source No. of Cattle using the source No. of Sheep/Goats using the source Area irrigated using the source (ha) Is the source protected? What is the depth of this borehole (m)? Type of Casing Casing size (inches) What is the current static water level of this borehole (m)? What is the yield of this borehole (m3/hr)? How long is this borehole operated in a day (hr)? What is the borehole draw down (m)? After pumping, how long does this borehole take to recover (hr)? What is the depth of this dug well (m)? What is the current static water level of this dug well (m)? What is the yield of this dug well (m3/hr)? How long is this dug well operated in a day (hr)? What is the dug well draw down (m)? After pumping, how long does this dug well take to recover (hr)? What is the depth of this dam (m)? What is the length of this dam (m)? What is the width of this dam (m)? What is the depth of this berkad (m)? What is the length of this berkad (m)? What is the width of this berkad (m)? What is the cumulative discharge rate of this spring (m3/hr)? What is the depth of this source (m)? What is the length of this source (m)? What is the width of this source (m)? What is the yield of the source (m3/hr)? What type of reservoir is used for this source? Reservoir capacity (m3) Pipeline type Pipeline length (m) How many House Holds (HH) are connected to this water source? How many kiosks/water points are connected to this source? How many animal troughs are connected to this source? Source used for water trucking during emergency? No. of trucks / day Average truck capacity (m3) Pump type Pump model Pump capacity (m3/hr) Pump level (m) Power source Generator/Solar type Generator capacity (kVA/kWh) What type/model is the solar used? What capacity is the solar (kWh)? Condition of supply system Additional notes on supply & distribution system condition Any visible physical problem (color, odor)? Please describe the color, odor and smell of water Temperature PH Electrical Conductivity (µs/cm) Total Dissolved Solids (mg/l) Water sample code. (if taken) Management type Water & Sanitation Committee (WSC)? Year established WSC members male WSC members female DIs water for human use charged? Current cost of 20 ltr jerrican (USD/20ltr) Is water for animal use charged? Current cost for Livestock (USD/100ltr) What is the name of the operator/caretaker for this water source? What is the phone number of the operator/caretaker? Which agency carried out last intervention on this water source? Recent interventions Last intervention date Proposed intervention description Additional Notes Metadata Tag
3347 DWGDLU021 Dug Well FGS_MoEWR Oct. 1, 2019 Gedo Luuq Hilaac Juba Water Co. 10/22/2018 Jubba Water 3 3.8002 42.5483 152.0 4.8 1571131572115.jpg yes Yes 4900 Yes 10.0 3.0 14.0 20.0 1.0 Concrete/Masonry tank PVC 700.0 700 no Grundfos 14.0 9.0 Submersible Pump No 29.1 7.57 710.0 360.0 Yes 0.05 No Elevated Concrete Water Tank 40M3, cholorin pump, PVC 700M pipeline and standby generator Strategic Water Sources Survey – WSS_NATl
3344 DWGDLU018 Dug Well FGS_MoEWR Oct. 1, 2019 Gedo Luuq Hilaac Community 6/29/2007 Rooble 3.7941 42.5449 155.0 5 3 1571131885406.jpg yes Yes 7350 No 12.0 5.0 12.0 12.0 2.0 Concrete/Masonry tank PVC 34.0 1050 6 yes 7 5.0 Grundfos 12.0 10.0 Submersible Pump Changfa 125.0 No 32.4 7.36 1240.0 620.0 Yes 0.05 Elavated concrete tank 40m3. 2013-04-27 Supply and distribution pipes 2000m, Concrete Tank 40M3, solar System 20 pannel, 1.5 flood protection wall, solar pump system controller lorentz and well head seal. Strategic Water Sources Survey – WSS_NATl
3342 DWGDLU016 Dug Well FGS_MoEWR Oct. 1, 2019 Gedo Luuq Dhuyacley SHRA 4/26/2016 Dhuyacley 3.7757 42.5391 146.0 4.9 1571131689955.jpg yes Yes 2450 Yes 7.0 4.0 12.0 9.0 1.0 Plastic tank PVC 2500.0 350 4 Grundfos 12.0 6.0 Submersible Pump DUSOL 1.2 No 33.3 7.47 1410.0 700.0 Yes Solar 8 panel 250w, 30m3 concrete tank , standby pump, kiosk rehabilitation, caretaker room and depth extension. Strategic Water Sources Survey – WSS_NATl
3341 DWGDLU015 Dug Well FGS_MoEWR Oct. 1, 2019 Gedo Luuq Kulmiye DRC 4/26/2017 Kulmiye 3.7743 42.5389 146.0 4.6 1569913067618.jpg yes Yes 4200 50 80 Yes 13.0 10.0 12.0 17.0 2.5 Plastic tank Stainless Steel 700.0 600 2 Grundfos 12.0 12.0 Submersible Pump Dayliff 2.5 No 31.0 7.3 3160.0 1570.0 No Fence 10 m2, 22 panel Solar system 250kw, depth extention, elevated concrete tank 40m3, kiosk 3, 2 troughs. Strategic Water Sources Survey – WSS_NATl
6772 BKTGBC001 Berkad Somaliland_MoWRD Oct. 1, 2019 Togdheer Burco Muraayada 0.0 Community 10-01-00 Murayad berkad1 8.7667 46.186 914.0 4.7 30 1569934484602.jpg no No It needs rehabilitation 400 0 500 4.0 8.0 8.0 Other Other 0.0 500 0 0 No Pump no 28.9 7.96 28.0 140.0 no yes 0.002 no Full rehabilitation, hygein and sanitation Strategic Water Sources Survey – WSS_NATl
3353 DWGDLU027 Dug Well FGS_MoEWR Oct. 1, 2019 Gedo Luuq Hilaac Jubba Water Com. 6/1/2013 Jubba Water 1 3.8018 42.5511 151.0 4.5 1 1571131426575.jpg yes Yes 3262 Yes 14.0 12.0 11.0 22.0 1.0 Concrete/Masonry tank PVC 50.0 466 no Grundfos 11.0 13.0 Submersible Pump No 29.7 7.76 1290.0 630.0 Yes 0.05 Well fence, 3m hight concrete wall for flood protection and standby Sumersible pump Strategic Water Sources Survey – WSS_NATl
6773 BKTGBC002 Berkad Somaliland_MoWRD Oct. 1, 2019 Togdheer Burco Muraayada 0.0 Community 04/28/1998 Murayada Berkad 2 8.7662 46.1869 905.0 4.7 20 1569935286042.jpg yes No It needs full conistruction 500 0 1000 4.0 10.0 6.0 Other Other 0.0 500 0 0 no No Pump 0 no 28.8 7.96 28.0 140.0 no no no It needs full conistruction Strategic Water Sources Survey – WSS_NATl
4086 DWMSBA037 Dug Well FGS_MoEWR Oct. 1, 2019 Middle Shabelle Balcad WarSheikh Community 5/4/1964 Cisiley DW 2.3802 45.7101 77.0 0 1571155953356.jpg yes Yes 1150 500 240 1950 0.0 Yes 50.0 38.0 13.0 1.1 7.5 Other Galvanised Steel 30.0 56 1 0 no Franklin 8.0 45.0 Submersible Pump Dose 11.0 No 29.2 8.25 2850.0 1440.0 Yes 11-10-96 3 1 No No Community Pipelines and pumps 2014-03-15 New borehole, solar system and animal troughs. Strategic Water Sources Survey – WSS_NATl
4096 DWMSCA001 Dug Well FGS_MoEWR Oct. 1, 2019 Middle Shabelle Cadaale Rage Elle Private 2/15/2015 Aqabley DW 2.6353 46.1233 6.0 6 1571154568385.jpg yes Yes 580 400 500 3000 0.0 No 13.0 10.0 24.0 3.0 no No 29.5 7.71 1460.0 730.0 No No Community Rehabilitation 2015-03-09 New borehole and full rehabilitation. Strategic Water Sources Survey – WSS_NATl
3363 DWGDLU037 Dug Well FGS_MoEWR Oct. 1, 2019 Gedo Luuq Jaziira Juba Water Company 4/26/2007 Juba Water 2 3.803 42.554 149.0 4.5 1571131498881.jpg no 0 No The source stopped function in 2013, when the water of the source become very salty. Furthermore, the generator is not functioning. 9800 Yes 10.0 7.0 12.0 20.0 1.0 Concrete/Masonry tank PVC 40.0 1400 no Grundfos 12.0 11.0 Submersible Pump Lister 9.2 No 30.2 7.39 1680.0 840.0 Yes 0.05 Generator 30 KVA, Submersible Pump, PVC pipeline 400m, Strategic Water Sources Survey – WSS_NATl

Donors

SWALIM is a multi-donor project managed by FAO and currently funded by The European Union, AICS, SDC, FCDO and Government of France

Donors