Id | Code | Select the type of water source being inspected | Select the agency inspecting this water source | Enter the date of source inspection | Region | District | Enter the name of settlement / village where the source is located | Distance to nearest settlement (KM) | Select the agency that established this water source | Enter the date when the source was established | Enter the water source name | Source gpspoint | Enter water source Latitude in decimal degrees | Enter water source Longitude in decimal degrees | Enter Elevation (m.a.s.l) | Enter GPS Precision (m) | Enter number of water sources in a cluster | Water Source Photographs | Select the category of users for this water source | Is this a permanent status water source? | For how many months in a year is this water source in use (#)? | Is this water source currently functioning? | Non functioning reason | No. of persons using | No. of Camels using the source | No. of Cattle using the source | No. of Sheep/Goats using the source | Area irrigated using the source (ha) | Is the source protected? | What is the depth of this borehole (m)? | Type of Casing | Casing size (inches) | What is the current static water level of this borehole (m)? | What is the yield of this borehole (m3/hr)? | How long is this borehole operated in a day (hr)? | What is the borehole draw down (m)? | After pumping, how long does this borehole take to recover (hr)? | What is the depth of this dug well (m)? | What is the current static water level of this dug well (m)? | What is the yield of this dug well (m3/hr)? | How long is this dug well operated in a day (hr)? | What is the dug well draw down (m)? | After pumping, how long does this dug well take to recover (hr)? | What is the depth of this dam (m)? | What is the length of this dam (m)? | What is the width of this dam (m)? | What is the depth of this berkad (m)? | What is the length of this berkad (m)? | What is the width of this berkad (m)? | What is the cumulative discharge rate of this spring (m3/hr)? | What is the depth of this source (m)? | What is the length of this source (m)? | What is the width of this source (m)? | What is the yield of the source (m3/hr)? | What type of reservoir is used for this source? | Reservoir capacity (m3) | Pipeline type | Pipeline length (m) | How many House Holds (HH) are connected to this water source? | How many kiosks/water points are connected to this source? | How many animal troughs are connected to this source? | Source used for water trucking during emergency? | No. of trucks / day | Average truck capacity (m3) | Pump type | Pump model | Pump capacity (m3/hr) | Pump level (m) | Power source | Generator/Solar type | Generator capacity (kVA/kWh) | What type/model is the solar used? | What capacity is the solar (kWh)? | Condition of supply system | Additional notes on supply & distribution system condition | Any visible physical problem (color, odor)? | Please describe the color, odor and smell of water | Temperature | PH | Electrical Conductivity (µs/cm) | Total Dissolved Solids (mg/l) | Water sample code. (if taken) | Management type | Water & Sanitation Committee (WSC)? | Year established | WSC members male | WSC members female | DIs water for human use charged? | Current cost of 20 ltr jerrican (USD/20ltr) | Is water for animal use charged? | Current cost for Livestock (USD/100ltr) | What is the name of the operator/caretaker for this water source? | What is the phone number of the operator/caretaker? | Which agency carried out last intervention on this water source? | Recent interventions | Last intervention date | Proposed intervention description | Additional Notes | Metadata Tag |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
8360 | — | Borehole | FGS Ministry of Energy and Water Resources | March 14, 2022 | Hiraan | beled_weyne | Gasle | 35.0 | ADRA | 18/10/2021 | Ceelka gasle | — | 4.9287959 | 45.1598713 | 159.0 | — | 4 | — | rural | no | 1 | No | Lack of water tanker and error for solar system | 800 | 500 | 200 | 300 | 0.0 | — | 230.0 | pvc | 8.0 | 80.0 | 30.0 | 1.0 | 18.0 | 2.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Other | 0.0 | PVC | 0.0 | 80 | 0 | 0 | no | — | — | Submersible Pump | Comoco submersible pump | 5.0 | 15.0 | Solar | — | — | — | 240.0 | fair | Lack of technical for the solar system installation | no | — | — | — | — | — | — | Utility/Local Authority | — | — | — | — | no | — | no | — | — | — | — | — | — | Generator, and tanker | — | — |
7217 | — | Borehole | Puntland Ministry of Energy Minerals and Water | March 14, 2022 | Bari | iskushuban | Camaan | 2.0 | Other | 29/01/2020 | Camaaan borehole | — | 10.1725041 | 49.8349062 | 407.0 | — | 1 | — | rural urban | yes | — | Yes | — | 1500 | 4000 | — | 12000 | — | — | 280.0 | pvc | 8.0 | 250.0 | 12.0 | 15.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 50.0 | Galvanised Steel | — | — | 2 | 2 | yes | 7 | 9.0 | Submersible Pump | Lowara | — | — | Hybrid - Solar/Generator | Perkins | 45.0 | GPS300-300 | 25.8 | good | But the village has no water supply, in addition to that the area is over population | no | — | 24.2 | 7.35 | 1950.0 | 956.0 | — | Communal | yes | 14/06/2007 | 8 | 3 | no | — | yes | — | — | — | — | — | There is no intervention up to its establishment. | 1: Replacement of main raining pipes immediately. 2: Fencing. 3: Construction of another elevated water tank due to increased demand. 4: Construction of another water troughs due increased demand of lvestock. 5: Construction of caretaker room. 6: pipe extention in order to supply the settlement. | — | — |
8504 | — | Dam | FGS Ministry of Energy and Water Resources | March 14, 2022 | Hiraan | beled_weyne | Feerfeer somalia | 50.0 | Community | 03/10/2019 | Berkad feerfeer | — | 5.0553435 | 45.1468108 | 211.0 | — | 5 | — | urban | no | 5 | Yes | — | 500 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 4.0 | 6.0 | 6.0 | — | — | — | — | — | Concrete/Masonry tank | 40.0 | Other | 0.0 | 80 | 0 | 0 | no | — | — | No Pump | — | — | — | — | — | — | — | — | good | Ok | no | — | — | — | — | — | — | Utility/Local Authority | — | — | — | — | no | — | no | — | — | — | Community | 3-Jun-20 | Rehabilitation | Rebuilding | — | — |
7153 | — | Dug Well | FGS Ministry of Energy and Water Resources | March 14, 2022 | Hiraan | beled_weyne | Bacaad | 20.0 | Personal owner( shaqsi dhistay) | 23/08/2008 | Bacad water distribution | — | 4.8672164 | 45.1564395 | 158.0 | — | 3 | — | urban | yes | — | Yes | — | 10000 | — | — | — | — | — | — | — | — | — | — | — | — | — | 8.0 | 1.0 | 15.0 | 8.0 | 2.0 | 0.0 | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 20.0 | PVC | 300.0 | 7428 | 0 | 0 | yes | 20 | 35.0 | Surface mounted Pump | Dynamos | 5.0 | — | Generator | Ghanfai generator | 12.0 | — | — | poor | Lack of generator | no | — | — | — | — | — | — | Private/Individual | — | — | — | — | yes | 0.01 | yes | — | — | — | Community | 7-Sep-17 | Rehabilitation | Concrete water tanker 200m, generator or solar, Dynamos, borehole | — | — |
7152 | — | Dug Well | FGS Ministry of Energy and Water Resources | March 14, 2022 | Hiraan | beled_weyne | Burqaniinyo | 30.0 | Community | 16/11/2017 | Kabxanle | — | 4.8821069 | 45.2375023 | 172.0 | — | 3 | — | rural | yes | — | Yes | — | 2000 | 500 | 100 | 5000 | 0.0 | — | — | — | — | — | — | — | — | — | 8.0 | 2.0 | 10.0 | 12.0 | 1.0 | 1.0 | — | — | — | — | — | — | — | — | — | — | — | Other | 0.0 | PVC | 0.0 | 285 | 0 | 5600 | no | — | — | Hand Pump | Hand pump | 8.0 | — | — | — | — | — | — | poor | It need repair for generator or replacing new generator | no | — | — | — | — | — | — | Utility/Local Authority | — | — | — | — | yes | 0.02 | yes | — | — | — | Community | 8-May-19 | Dug depth | Tank for concrete for capacity 200 M3, solar and pump for lowawara submersible pum | — | — |
7064 | — | Dug Well | FGS Ministry of Energy and Water Resources | March 14, 2022 | Hiraan | beled_weyne | Ceel muslim | 18.0 | Community | 09/04/2019 | Muciin water supply | — | 4.8474975 | 45.2344463 | 170.0 | — | 15 | — | urban | yes | — | Yes | — | 4000 | — | — | — | — | — | — | — | — | — | — | — | — | — | 20.0 | 14.0 | 20.0 | 10.0 | 5.0 | 1.0 | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 15.0 | PVC | 1500.0 | 572 | 0 | 0 | no | — | — | Hand Pump | Dynamos/ diinimo | 10.0 | — | — | — | — | — | — | poor | They need pump and solar because the generator used failed to produce pressure water | no | — | 0.0 | — | — | — | — | Private/Individual | — | — | — | — | yes | 0.1 | yes | — | — | — | Authority | 9-Jul-21 | Repair | Generator, Dynamos, solar system | — | — |
7888 | — | Borehole | Puntland Ministry of Energy Minerals and Water | March 14, 2022 | Mudug | galkayo | Heema | 0.3 | ADA | 14/03/2004 | Heema BH | — | 7.1430376 | 47.5313058 | 344.0 | — | 1 | — | urban | yes | — | Yes | — | 3100 | — | — | — | — | — | 180.0 | pvc | 8.0 | — | 16.0 | 14.0 | — | 2.4 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 130.0 | PVC | 1500.0 | 70 | 2 | 2 | no | — | — | Submersible Pump | — | 11.0 | 162.0 | Generator | Lesory somer | 45.0 | — | — | good | — | yes | Colorless and odorless | 31.8 | 7.85 | 2645.0 | 1318.0 | — | Communal | yes | 15/03/2012 | 3 | 2 | no | — | no | — | — | — | NRC | 14/02/2021 | 1. Construction of new elevated tank | 1. Installation of solar power. 2. Panels. 3. Extension of pipelines. 4. Rehabilitation of pump and riser pipes. | — | — |
7249 | — | Borehole | Puntland Ministry of Energy Minerals and Water | March 14, 2022 | Mudug | galkayo | Margaaga | — | ISRC | 14/03/2009 | Margaaga BH | — | 7.2191715 | 47.5372463 | 344.0 | — | 1 | — | urban rural | yes | — | Yes | — | 7448 | 50 | — | 2000 | — | — | 194.0 | pvc | 8.0 | 80.0 | 8.0 | 12.0 | — | 2.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 31.0 | PVC | 3000.0 | 200 | 8 | 1 | no | — | — | Submersible Pump | Lowara | 7.5 | 162.0 | Hybrid - Solar/Generator | Parkins | 30.0 | BR-M300W | 15.0 | good | — | yes | Colorless and odorless | 33.5 | 7.35 | 3405.0 | 1698.0 | — | Communal | yes | 14/03/2012 | 3 | 4 | yes | 0.05 | yes | — | — | — | NRC | 14/02/2021 | 1. Construction of new elevated tank. | 1. Installation of pump 2. Construction animal troughts 3. Fancing 4. Fuel supporting | — | — |
7039 | — | Dug Well | FGS Ministry of Energy and Water Resources | March 14, 2022 | Hiraan | beled_weyne | Hilikilyo | 12.0 | Community | 09/12/2005 | Hilikilyo | — | 4.7878325 | 45.2164478 | 155.0 | — | 5 | — | rural urban | yes | — | Yes | — | 2100 | 1500 | 200 | 2560 | 0.0 | — | — | — | — | — | — | — | — | — | 15.0 | 10.0 | 15.0 | 12.0 | 2.0 | 3.0 | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 50.0 | PVC | 0.0 | 300 | 0 | 0 | no | — | — | Hand Pump | Dynamos | 10.0 | — | — | — | — | — | — | good | Ok | no | — | — | — | — | — | — | Utility/Local Authority | — | — | — | — | yes | 0.01 | yes | — | — | — | Community | 9-Sep-14 | Construction of elevator water tank | Generator | — | — |
7515 | — | Borehole | Puntland Ministry of Energy Minerals and Water | March 14, 2022 | Mudug | galkayo | Ceelgerdi 2 | — | Community | 14/03/2014 | Ceelgerdi BH 2 | — | 7.2318127 | 47.5488879 | 344.0 | — | 1 | — | rural | yes | — | Yes | — | 350 | 500 | — | 1500 | 4.0 | — | 190.0 | pvc | 8.0 | 135.0 | 13.3 | 8.0 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Concrete/Masonry tank | 16.0 | Galvanised Steel | 700.0 | 7 | 0 | 2 | yes | 7 | 8.0 | Submersible Pump | Lowara | 11.0 | 145.0 | Generator | Parkins | 45.0 | — | — | fair | Supply needs rehabilitation | yes | Colorless and odorless | 34.1 | 7.81 | 3110.0 | 1550.0 | — | Communal | yes | 14/03/2017 | 2 | 1 | yes | 0.05 | no | — | — | — | — | — | — | 1. Construction of koisks 2. Construction of new elevated tank 3. Installation of solar power 4. Rehabilitation of pump and riser pipes | — | — |
SWALIM is a multi-donor project managed by FAO and currently funded by The European Union, AICS, USAID, SDC, FCDO and Government of France