1 |
BHAWBA001 |
Borehole |
Somaliland_MoWRD |
11/26/2019 |
Awdal |
Baki |
Warqa dhigta |
3.0 |
Kuwait Government |
12-02-19 |
Warqa dhigta bore hole |
— |
10.1776 |
43.6166 |
561.0 |
4.9 |
1 |
— |
Urban |
Yes |
— |
Yes |
— |
— |
— |
— |
— |
— |
— |
30.0 |
PVC |
6.0 |
15.0 |
9.0 |
3.0 |
1.0 |
3.0 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
Steel tank |
10.0 |
PVC |
3.0 |
200 |
1 |
1 |
No |
— |
— |
No Pump |
Grundfos 15kW |
11.0 |
25.0 |
Solar |
— |
— |
6banal 280kv |
280.0 |
Good |
Is good |
Yes |
— |
28.4 |
7.75 |
960.0 |
480.0 |
— |
Communal |
— |
05-10-19 |
7 |
4 |
No |
— |
No |
— |
— |
— |
— |
— |
11/26/2019 |
Distribution water gabyn guard house extara pump water kioks |
— |
Strategic Water Sources Survey – WSS_NATl |
watersource.HistoricalWaterSource.None |
2 |
BHAWBA002 |
Borehole |
Somaliland_MoWRD |
11/28/2019 |
Awdal |
Baki |
Waraabe dareeri |
2.0 |
Kuwait Government |
28-04-19 |
Waraabe dareeri bore hole |
— |
10.2745 |
43.6708 |
432.0 |
4.9 |
1 |
— |
Rural Urban |
Yes |
— |
Yes |
— |
— |
200 |
0 |
4000 |
0.0 |
— |
48.0 |
PVC |
6.0 |
18.0 |
8.0 |
8.0 |
— |
2.0 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
Steel tank |
60.0 |
Stainless Steel |
3.0 |
0 |
1 |
1 |
No |
— |
— |
Submersible Pump |
Lowara 11kW |
9.0 |
45.0 |
Solar |
— |
— |
Banal 6 |
280.0 |
Good |
The condition of supply is good |
Yes |
— |
27.0 |
7.45 |
1860.0 |
930.0 |
— |
Communal |
— |
21-07-18 |
5 |
2 |
Yes |
0.5 |
No |
— |
— |
— |
— |
— |
— |
Guard houses piplene disturbution |
— |
Strategic Water Sources Survey – WSS_NATl |
watersource.HistoricalWaterSource.None |
3 |
BHAWBA003 |
Borehole |
Somaliland_MoWRD |
12/14/2019 |
Awdal |
Baki |
Hadayta |
1.0 |
Kuwait Government |
29-08-19 |
Hadayta bore hole |
— |
10.5198 |
44.0249 |
45.0 |
4.9 |
1 |
— |
Rural Urban |
Yes |
— |
No |
This bore hole is new |
— |
3000 |
0 |
8000 |
0.0 |
— |
60.0 |
Other |
— |
40.0 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
Other |
— |
Other |
— |
— |
— |
— |
— |
— |
— |
No Pump |
— |
— |
— |
— |
— |
— |
— |
— |
Fair |
The condition of supply system is very poorly designed |
No |
— |
— |
— |
— |
— |
— |
Communal |
— |
16-12-18 |
5 |
2 |
No |
— |
No |
— |
— |
— |
— |
— |
— |
Increase depth water quality tasting animal though water kiosks pipeline distribution and genatore |
— |
Strategic Water Sources Survey – WSS_NATl |
watersource.HistoricalWaterSource.None |
4 |
BHAWBA004 |
Borehole |
Somaliland_MoWRD |
12/14/2019 |
Awdal |
Baki |
Abdi geedi |
0.0 |
IR - Islamic Relief |
14-12-17 |
Abdi geedi bore hole |
— |
10.5086 |
44.0493 |
38.0 |
4.9 |
1 |
— |
Rural Urban |
Yes |
— |
Yes |
— |
— |
500 |
0 |
3000 |
0.0 |
— |
100.0 |
PVC |
6.0 |
16.0 |
5.0 |
10.0 |
— |
0.0 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
Concrete/Masonry tank |
50.0 |
PVC |
50.0 |
0 |
2 |
2 |
No |
— |
— |
— |
Groundfos Denmark |
9.0 |
90.0 |
Hybrid - Solar/Generator |
France mkyl |
13.0 |
Banal 7 |
400.0 |
Good |
The condition of supply system is very good |
Yes |
— |
29.3 |
8.09 |
3800.0 |
1100.0 |
— |
Communal |
— |
09-07-18 |
1 |
2 |
No |
— |
No |
— |
— |
— |
Other |
Solor changes. Built guard house covered water tanks |
05/27/2018 |
Pipeline rehabilitation and animal thoughts water kiokes addition pipeline distribution |
— |
Strategic Water Sources Survey – WSS_NATl |
watersource.HistoricalWaterSource.None |
5 |
BHAWBA005 |
Borehole |
Somaliland_MoWRD |
11/28/2019 |
Awdal |
Baki |
Ceel LA helay |
1.0 |
Kuwait Government |
16-06-12 |
Ceel La helay Bore hole |
— |
10.2685 |
44.0824 |
242.0 |
3.2 |
1 |
— |
Urban |
Yes |
— |
Yes |
— |
— |
— |
— |
— |
— |
— |
70.0 |
PVC |
6.0 |
60.0 |
7.0 |
12.0 |
1.0 |
12.0 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
Concrete/Masonry tank |
24.0 |
Stainless Steel |
500.0 |
0 |
3 |
2 |
No |
— |
— |
Submersible Pump |
Lolwara UK 12kW |
11.0 |
65.0 |
Solar |
— |
— |
Banal |
400.0 |
Fair |
Is very fairly |
Yes |
— |
30.9 |
7.32 |
2140.0 |
1100.0 |
— |
Communal |
— |
28-12-17 |
7 |
3 |
Yes |
0.2 |
No |
— |
— |
— |
Community |
Pump |
07/28/2018 |
Water kiosks and animal thoughts distribution systems |
— |
Strategic Water Sources Survey – WSS_NATl |
watersource.HistoricalWaterSource.None |
7 |
BHAWBA007 |
Borehole |
Somaliland_MoWRD |
12/14/2019 |
Awdal |
Baki |
Ceel La helay |
9.0 |
Private |
10-08-12 |
Fardaale farm bore hole |
— |
10.3257 |
44.1176 |
185.0 |
4.9 |
1 |
— |
Rural Urban |
Yes |
— |
Yes |
— |
— |
150 |
— |
800 |
9.0 |
— |
70.0 |
PVC |
8.0 |
30.0 |
12.0 |
24.0 |
— |
0.0 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
Steel tank |
14.0 |
Stainless Steel |
50.0 |
1 |
0 |
1 |
No |
— |
— |
Submersible Pump |
Lowara UK |
18.0 |
60.0 |
Generator |
Radiator chine |
16.0 |
— |
— |
Good |
Is good condition |
Yes |
— |
30.7 |
7.76 |
2000.0 |
10.0 |
— |
Private/Individual |
— |
— |
— |
— |
No |
— |
No |
— |
— |
— |
— |
Pipeline and pump change |
07/11/2018 |
— |
— |
Strategic Water Sources Survey – WSS_NATl |
watersource.HistoricalWaterSource.None |
8 |
BHAWBO001 |
Borehole |
Somaliland_MoWRD |
12/04/2019 |
Awdal |
Borama |
Quljeed |
2.0 |
— |
04-08-17 |
Quljeed BH3 |
— |
10.0942 |
43.0154 |
1574.0 |
3.2 |
0 |
— |
Rural |
Yes |
— |
Yes |
— |
— |
0 |
50 |
200 |
5.0 |
— |
100.0 |
GI |
8.0 |
30.0 |
5.0 |
2.0 |
— |
0.0 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
Steel tank |
20.0 |
Galvanised Steel |
20.0 |
0 |
1 |
1 |
No |
— |
— |
Submersible Pump |
Lowara |
18.0 |
66.0 |
Generator |
Perkins |
83.0 |
— |
— |
Good |
— |
No |
— |
19.0 |
7.53 |
629.0 |
884.0 |
— |
Communal |
— |
— |
— |
— |
Yes |
0.1 |
Yes |
— |
— |
— |
— |
— |
— |
Installation of sollar
Increasing the number of animal troughs
Replacement pip line about 3 inch
Construction concrete water tank |
— |
Strategic Water Sources Survey – WSS_NATl |
watersource.HistoricalWaterSource.None |
9 |
BHAWBO002 |
Borehole |
Somaliland_MoWR |
01/07/2014 |
Awdal |
Borama |
Qolijeed |
— |
COOPI - Cooperazione Internazionale |
01-06-96 |
Qolijeed |
— |
10.0878 |
43.029 |
1547.0 |
— |
— |
— |
Rural |
Yes |
— |
Yes |
— |
500 |
500 |
300 |
2000 |
— |
— |
98.0 |
— |
— |
55.0 |
5.0 |
4.0 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
36.0 |
— |
2000.0 |
— |
— |
— |
— |
— |
— |
Submersible Pump |
SPI 5 |
— |
70.0 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
7.9 |
1259.0 |
843.0 |
— |
Public |
— |
— |
— |
— |
— |
0.03 |
— |
0.15 |
— |
— |
— |
— |
— |
Generator Room, pump force is small it needs Spi11 or 10 kw. |
— |
Strategic Boreholes Survey – BHS |
watersource.HistoricalWaterSource.None |
10 |
BHAWBO003 |
Borehole |
Somaliland_MoWRD |
12/04/2019 |
Awdal |
Borama |
Quljed |
2.0 |
— |
04-07-96 |
Quljed BH1 |
— |
10.0879 |
43.029 |
1547.0 |
3.2 |
0 |
— |
Rural Urban |
Yes |
— |
Yes |
— |
— |
50 |
100 |
200 |
0.0 |
— |
100.0 |
GI |
8.0 |
61.3 |
12.0 |
4.0 |
— |
0.0 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
Concrete/Masonry tank |
48.0 |
PVC |
3000.0 |
50 |
2 |
4 |
Yes |
3 |
8.0 |
Submersible Pump |
Grundfos |
3.0 |
102.0 |
Hybrid - Solar/Generator |
Perkins |
75.5 |
Photovoltaic |
15.38 |
Good |
— |
No |
— |
15.0 |
8.28 |
1106.0 |
786.0 |
— |
Communal |
— |
04-07-17 |
2 |
1 |
Yes |
0.3 |
Yes |
— |
— |
— |
Other |
Construction of elevated water tank
Installation of solar
Generator
Construction room
Pipe line extention |
05/09/2019 |
Construction room staff |
— |
Strategic Water Sources Survey – WSS_NATl |
watersource.HistoricalWaterSource.None |
11 |
BHAWBO004 |
Borehole |
Somaliland_MoWRD |
12/04/2019 |
Awdal |
Borama |
Quljeed |
5.0 |
— |
06-08-18 |
Quljeed BH2 |
— |
10.0839 |
43.0488 |
1529.0 |
3.2 |
0 |
— |
Rural |
Yes |
— |
Yes |
— |
— |
0 |
80 |
200 |
30.0 |
— |
100.0 |
GI |
8.0 |
30.0 |
4.0 |
5.0 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
Concrete/Masonry tank |
16.0 |
Galvanised Steel |
50.0 |
0 |
2 |
3 |
No |
— |
— |
Submersible Pump |
Lowara |
1.5 |
78.0 |
Solar |
— |
— |
Photovoltaic |
1.5 |
Good |
— |
No |
— |
27.0 |
7.85 |
1248.0 |
881.0 |
— |
Communal |
— |
— |
— |
— |
Yes |
0.1 |
Yes |
— |
— |
— |
— |
— |
— |
Generator
Increasing the number of solar |
— |
Strategic Water Sources Survey – WSS_NATl |
watersource.HistoricalWaterSource.None |